Page 46 
 
Advanced Control Programming (ACP) 
 
Your HMS 1100 can be programmed to do automated control and security functions on a time schedule or in response to an event 
occurring in the system.  You may program the following items: 
 
 
Unit Numbers: On, Off, On for time, Off for time, Dim, Brighten, Dim for time, Brighten for time, Level, and Scene 
 
Settings for HMS Communicating Thermostats 
 
Temperatures: Low and High temperatures 
 
All lights On, All Off 
 
Security modes Off, Day, Night, Away, Vacation, Day(Instant), and  Night(Delay) and bypass and restore zones 
 
Buttons (Events) 
 
Messages: Show, Log, Clear, Say, Phone, and Send 
 
The HMS 1100 executes programs: 
 
 
Once at a certain time on a certain date (One-Time Program) 
 
On a certain date every year (Yearly Program) 
 
Repeatedly (Repeating Programs) 
 
In response to an event (Button Programs) 
 
You can also specify 2 conditions in each program, so that they only run under certain circumstances. 
 
Every line of programming in the HMS 1100 controller consists of three pieces.  Each line must have at least an event (when) and 
a result (command).  The "&IF" statement (condition) is optional in all programming lines. 
 
The program may specify up to 2 conditions that must be true for the program to execute.  When programming from the console, 
only 1 condition can be selected.  If 2 conditions must be specified for a single program line, it must be entered using the PC 
Access Software. 
 
Each program can be set up to execute at a certain time of day or on the occurrence of a particular event in the system.  When this 
time or event occurs, the programmed action will be taken if, and only if, the specified condition(s) is also true at that time. 
 
The Program menu allows you to add, review, change, and delete automation programs.  To enter the Program menu, from the 
Setup menu, press the 3 (PROG) key. 
 
   SET 
UP 
PROGRAMS
 
 
 
 
1=ADD   2=SHOW  3=DELETE
 
 
1 = Add Programs 
 
The 1 (ADD) key is used to add new automation programs to the system.  When you press the 1 (ADD) key, the Edit Program 
menu is displayed which allows the various parts of a program to be specified - See Edit Program.  You may edit each part of the 
program as specified under Edit Program.  Press the ' # ' key at the Edit Program menu to show the newly entered program.  
Press the ' # ' key again to save the program, or press the ' * ' key to return to the Edit Program menu to cancel entry of the new 
program and return to the Set Up Programs menu. 
 
Once the new program is entered, the display will return to the Set Up Programs menu. 
 
2 = Show Programs 
 
The 2 (SHOW) key is used to review, edit, and delete existing programs.  From the Set Up Program menu, press the 2 (SHOW) 
key.  The display prompts you to specify which program to be reviewed. 
 
 
 
 
1=CTRL  2=SEC   3=BTTN
 
 
 
 
4=ALL   5=TEMP  #=EVERY