Error messages when validation fails
Test button
When you create your external location, the system validates the location. The system
checks the following aspects:
1.
Check the remote folder syntax.
Check the validity of the hostname.
Check the possibility to connect to the remote host.
Check if the remote destination exists.
Check the possibility to write on the remote destination.
When one of these steps fails, an error message and error code are generated.
#
Possible Causes
Error code
For SMB locations: check the remote folder <remotefolder>
syntax conforms to \\hostname\share\[\folder\...] or \\<IP_ad-
dress>\share[\folder\...]
For FTP locations: check the remote folder <remotefolder>
syntax conforms to hostname/folder[/subfolder/…] or <IP_ad-
dress>/folder/[/folder/…]
For WebDAV locations: check the URL <HTTP URL> (for
example: http://example.webdav.org:8080/repository/).
2
Check if the hostname is OK.
Check if the printer is connected to customers network.
Check the network settings of the printer in Océ Express
WebTools:
- Primary DNS suffix
- Preferred DNS server
- NetBios over TCP/IP is set to "Enabled"
- Subnet mask
- Default gateway
Check with the System administrator if the DNS server can re-
solve the hostname to an IPv4 address.
Check that printers Security level is set to normal.
For SMB destination: if IPV6 protocol is enabled on the printer:
- replace hostname by its IPv4 address (if IPV6 must be enabled)
- or Disable IPv6 on the printer (if IPV6 can be disabled)
If any of previous mentioned checks does not solve the problem:
enter the remote host IPv4 address instead of the hostname
3
Chapter 3 - Define your Workflow with Océ Express WebTools
155
Error messages when validation fails