3. Installation
RuggedCom® RuggedBackbone™
28
RX1510 Installation Guide Rev 104
3.10. DDS Rx and Tx LED Indications
The DDS module features Rx and Tx LED indicators that display transmit and receive status.
Figure 3.22. DDS Module Rx and Tx LED Indicators
The following tables describe the DDS module Rx and Tx LED status indications:
Rx LED Color
Status
GREEN
Frame sync detected and signal OK.
YELLOW
Signal OK, but no frame sync.
RED
Loss of signal.
OFF
The interface is not enabled.
Table 3.7. DDS Rx LED Indications
Tx LED Color
Status
GREEN
The interface is enabled and remote device has no errors.
YELLOW
The interface is in loopback mode.
RED
Loss of signal or receiving any of OOS, UNM, or UMC codes: the remote device is out of service
or has problems with the signal.
OFF
The interface is not enabled.
Table 3.8. DDS Tx LED Indications
3.11. SFP Optics – Installation, removal, and precautions
The RX1510 can be ordered with SFP (Small Form-factor Pluggable) pluggable optics modules.
SFP modules can be safely inserted and removed while the chassis is powered and operating.
When inserting or removing optics, observe the following precautions:
• Ensure that dust caps are mounted on SFP cages at all times, unless you are in the process
of inserting or removing an SFP module. The dust caps prevent the accumulation of residue or
particles that might inhibit proper operation.
• Ensure  that  you  have  properly  discharged  any  possible  electrostatic  build-up  to  prevent
electrostatic discharges (ESD). This can be accomplished by proper grounding through an ESD
wrist strap, or by touching earth or chassis ground before installing or removing optical modules.
ESD can damage or shorten the life of optical modules when they are not plugged into a chassis.
• Ensure  that  SFP  optical  modules  are  always  stored  in  an  ESD-safe  bag  or  other  suitable
ESD-safe environment. Keep SFP modules free from moisture and store them at the proper
temperature (-40°C to +85°C).
• Disconnect all cables from the SFP module before inserting or removing the module.
• Use only components certified by RuggedCom Inc. with RuggedCom products. Damage can
occur to optics and product if compatibility and reliability have not been properly assessed.