Technicolor - Thomson Electronic Accessory Gecko Frames Signal Processing System ユーザーズマニュアル

ページ / 52
Gecko Frames Instruction Manual
23
Frame Monitor and Network Interface Modules
 
The total frame power required is less than 30 watts; therefore, the convec-
tion frame may be used.
With ten modules, the total frame power required is greater than 30 watts 
and an 8900TF or 8900TFN forced-air frame must be used.
Frame Monitor and Network Interface Modules
8900 frame configuration supports the use of either the Frame Monitor or 
the 8900NET Network Interface module. The Frame Monitor module pro-
vides alarm reporting for the Frame Alarm only. The 8900NET Network 
Interface module provides full functionality of the frame communication 
buses including:
Frame Alarm,
RS-232 Configuration, and
10Base-T Ethernet.
Refer to the 8900NET Network Interface Module Instruction Manual.
Table 5.  Module Power Dissipation, example 2
Module
Quantity
Power Per 
Module
Total Power
8836
1
3 Watts
3 Watts
8916
2
6 Watts
12 Watts
8960DEC
without Frame Sync
3
6.5
19.5
8941
4
6 Watts
24 Watts
Total Frame Power