Alarm Lock Trilogy PDL3000 開発者ガイド

ページ / 36
ACTIVITY 
LED 
SOUNDER 
COMMENTS 
Keypress 
1 RED Flash 
1 Beep 
Normal Operation 
Access Granted or Remote Release 
3 GREEN Flashes 
3 Beeps 
Remote release enabled through activa-
tion of relay 
Invalid Code 
6 RED Flashes 
6 Beeps 
Re-enter User Code 
Successful Program Entry 
2 GREEN Flashes 
2 Beeps 
When in Program Mode 
Unsuccessful Program Entry 
7 RED Flashes 
7 Beeps 
When in Program Mode 
Exit Program Mode 
1 RED, 2 GREEN Flashes 
10 Beeps 
 
Valid but Disabled Code 
1 GREEN, 4 RED Flashes 
1 long, 5 short beeps 
Code exists in memory, but disabled 
Low Battery 
YELLOW Flash during key 
presses 
Long Beep 
See page 11 before changing batteries 
User Code Entered 
YELLOW Flash 
Sequence of 7 Beeps 
Repeated 4 Times  
Non-fatal memory or clock error has been 
detected.  Under this condition, 
unexpected operation is possible.  Re-
move power and restart. 
Programming Key Sequence
Programming  
Information 
General Program Mode Information 
If a wrong key is pressed during code entry,  hold any key continuously until the error sound is heard (7 short beeps), this will clear the entry.  Re-enter the key 
sequence again.   
All program sequences are followed by the 
: key; 2 short beeps indicate a successful program sequence. 
Enabling/Disabling Users (By User Number) 
3. Disable User  
; 3      ; [ _ _ _ ] :
 
4. Enable User  
; 4      ; [ _ _ _ ] :
 
User Number must be between 2 and 2000.   
NOTE:  Will Enable/Disable users even if the user is associated with an enabled group. 
Conventions Used in this Manual 
LED and Sounder Indicators 
The PDL Series locks provide visual and audible keypad feedback.  With a fully charged battery, the LED and sounder feed-
back is as follows: 
Minimum Required Program Level 
 
Program Levels are abbreviated as follows: 
 
M = Master 
4 = Installer  
3 = Manager 
2 = Supervisor 
1 = Print Only Users 
 
This Program Level abbreviation is the 
minimum program level required to 
access the particular Function.  (The 
higher the level, the more programming 
tasks the User is allowed, with Master 
allowing all tasks). 
Function  
Description 
Function  
Number 
Function Name