Starting up the PLC with a bootable and activated 
program
After each startup, the activation of menu item LOAD or REBOOT, 
the PLC will create an executable program from the activated 
program which it will store in the working memory. This will over-
write any executable program that is present. The activated 
program is retained.
If the OMS is set to RUN-P or RUN, the PLC runs a warm start: the 
(POU) variables and the variables declared as PERSISTENT are 
initialised.
Entering parameters or status modifications
Any changes to PLC parameters or states such as Start/Stop you 
wish to make can be password protected. To do this proceed as 
follows.
Without a password
The program is processed according to the position of the oper-
ating mode selector switch (OMS). If the OMS is set to RUN, the 
program is processed and the display shows:
X
Press the MSS to reach the main menu.
Setting the OMS to RUN-P, STOP or MRES will execute the function 
accordingly.
With password
An assigned password will freeze the status of the PLC and the 
parameters at the time the password was assigned. In this way, 
the position of the OMS can also be frozen to a particular position, 
such as RUN. In the event of a power failure, the RUN status will 
be retained when power is restored. The display shows:
The program is processed and the RUN LED is lit.
You can only reach the main menu by entering the password:
X
Turn the MSS so that the display shows PASSWORD. 
Press the MSS so that the display shows:
If the position of the OMS was changed, a message will indicate 
how the OMS should be set, such as Key: RUNP. 
X
Switch the OMS to this position to clear the message.
X
Entering an incorrect password will return you to the PASSWORD 
menu.
h
If you have loaded the program but not a bootable version 
of it, the program will be deleted on startup.
Figure 65:
Storing programs in the memory after Download/
Create Boot Project 
* The program is copied on LOAD, REBOOT, Power On
PLC
PC with XSoft
Executable program 
Testprog
Login: the program 
Testprog.pro is loaded
Working memory
Program memory
Testprog.pro
Create Boot Project: a 
bootable and activated 
version is generated from 
the Testprog.pro program.
Hard disk
*
12:34:44
R
RUN
PRONAM.PRO
>MAIN MENU
Time, event message, PLC status
PLC status (irrespective of OMS)
Program name
Menu entry
+ = Password active
R = RUN (OMS status)
17:10:37 !+R
RUN
PRONAM.PRO
>MAIN MENU
PASSWORD
***
>BACK