Functions of the Operator 
Module
12/01 AWB2700-1428GB
36
Startup with configuration scan
On startup the PLC system always scans the modules of which the 
PLC is made up. If the configuration does not change, for example, 
after commissioning has been completed, the configuration can be 
”frozen” for diagnostic tasks.
For this disable the AUTOCONFIG function:
X
Choose MAIN MENU DEVICE HARDWARE 
AUTOCONFIG. 
The cursor will be positioned on ON:
X
Turn the MSS until the display shows OFF.
X
Press the MSS. The word ENTER will appear on the display.
X
Press the MSS to return to the menu.
This function can be re-activated at any time.
The next time that the PLC is started up the PLC will detect if any 
modules are missing or faulty. This will be indicated by the lit SF 
LED.
The following error text will appear in the DIAGNOSTICS ERROR 
menu:
The number 1 in the designation XC-NET-1 indicates the module:
Error and event messages
Error messages
The SF LED will be lit in the event of an error, and ! will appear in 
the display.
The following errors will cause an error message to be output:
The type of error with date and time is displayed in the Diagnostics 
menu under ERROR.
The error message can be deleted as described below, together 
with the event messages:
X
Choose menu item MAIN MENU r DIAGNOSTICS CLEAR.
The display shows:
X
Turn the MSS until NO is replaced by YES.
X
Press the MSS.
X
Turn the MSS: BACK will be replaced with ENTER.
X
Press the MSS to reach the next higher menu.
Event message
Events are written with the time and date for additional infor-
mation.
Events include:
The events are displayed via DIAGNOSTICS EVENT. Turn the 
MSS to go through each message in the list.
Calling up the EVENT menu will clear the exclamation mark. All 
event messages are cleared with the error message via the CLEAR 
menu item in the diagnostics menu.
Number
(Hardware) address of the module
0
CE000
1
CC000
2
D4000
AUTOCONFIG:
ON
BACK
05.12_15:32
XC-NET-1
NOT DETECTED
BACK
15:21:10 !P
RUN-P
SAWING.PRO
>MAIN MENU
From the system
PROG: ??? – No program loaded. Other 
system errors are listed in the Appendix
From the operator 
module
Battery discharged or not present
From the local I/O 
modules
XION not detected
h
Other error messages are explained in the Appendix.
h
The message will be retained if the error is still present.
System
Start program or Stop program
XI/ON modules
XION Diag extended, an error has occurred, e.g. 
short-circuit at an output, that is displayed via the 
extended diagnostics.
XI/ON param conf failed – the set configuration 
does not match the actual configuration
CLEAR:
NO
BACK