Bosch 500 ユーザーズマニュアル

ページ / 8
MIC Series 500 Camera
 MIC 500 Series Camera Quick Start Guide | en
5
Bosch Security Systems, Inc.
User’s Manual
F.01U.173.601 | 2.0 | 2010.11
The MIC 500 Series camera has a security attachment point for attaching to a safety chain 
(not supplied), which in turn should be attached to a secure part of the structure during 
installation or removal.
1.2
Safety Earthing of the MIC 500 Series Camera
The electronics and housing of the MIC 500 Series camera are electrically isolated; however, 
the housing should be safety earthed regardless. This safety earth should be a bonding 
connection, such as one of the securing bolts, to the outside case of the camera. The camera 
should be earthed at one point only to prevent earth loops and thus hum bars appearing on 
the camera picture in the control room.
Shielded Composite Cable Connections
Note: all connections must be made.
Mains Power and Video Connections
WARNING! 
Use caution when installing the MIC 500 Series camera. Follow common sense precautions 
such as fitting a safety chain.
Composite Cable Wire Color
Function
MIC PSU Terminal Block PCB Marking
Red
AC supply
HD3-1
Power
Green
AC supply return
HD3-2
Power
White
RX +
Hd3-3
RxB
Yellow
Rx -
HD3-4
RxA
Drain Wire
Ground
HD3-5
GND
Blue
Tx -
HD3-6
TxA
Violet
Tx +
HD3-7
TxB
Coax Core
Video
HD3-8
Video
Coax Screen
Video return
HD3-9
Vid 0V
Black (optional)
Tamper switch
HD3-10
Tamp Sw
Orange (optional)
Wash drive
HD3-11
Wash
Brown
Heater+
HD6-1
Gray
Heater-
1
HD6-2
1. Please refer to the MIC Series Power Supply Manual for details on connecting MIC 500 Series cameras with 
heaters and other auxiliary equipment.
Mains
Live
HD1-1
Neutral
HD1-2
Earth Connection 
Already made
Video
Video BNC CN1
Connection
Core
Video to Control Room
Screen
Video GND to Control Room