Zephyr ZSAM90C オーナーマニュアル

ページ / 44
5
Duct pieces 
Total
Equivalent number
length  x used      =
3- 1/ 4” x 10”
Rect.,
straight
1 Ft.           x (      )   =
Ft.    
8” Round,
straight
1 Ft.           x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect. 90
0
elbow
15 Ft.         x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect. 45
0
elbow
9 Ft.           x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect. 90
0
flat elbow
24 Ft.         x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect.
wall cap
with damper
30 Ft.         x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect. to
6” round
transition
5 Ft.           x (      )   =
Ft.    
3- 1/ 4” x 10”
Rect. to
6” round
transition
90
0  
elbow
20 Ft.         x (      )   =
Ft.    
6” Round,
90
0  
elbow
15 Ft.         x (      )   =
Ft.    
6” Round,
45
0  
elbow
9 Ft.           x (      )   =
Ft.    
Ft.    
7” Round,
straight
1 Ft.           x (      )   =
Ft.    
Subtotal column 1  =
Duct pieces 
Total
Equivalent number
length  x used      =
6”- 8” Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.    
Round
wall cap
with damper
30 Ft.         x (      )   =
Ft.    
7” or 8” 
Round,
90
0  
elbow
15 Ft.         x (      )   =
Ft.    
7” or 8” 
7” or 8” 
Round,
45
 
elbow
9 Ft.           x (      )   =
Ft.    
Ft.    
Ft.    
Ft.    
6”- 8” Round,
roof cap
30 Ft.         x (      )   =
Ft.    
7” or 8”
Round,
roof cap
30 Ft.         x (      )   =
Ft.    
Subtotal column 2  =
Subtotal column 1  =
Total ductwork      =
Maximum Duct  Length: 
For satisfactory air movement,
the total duct length of a 3 1/ 4” x 10” rectangular  6” or 7”
diameter round duct should not exceed 100 equivalent feet.
6” round to
3- 1/ 4” x 10”
rect. 
transition
1 Ft.           x (      )   =
Ft.    
6” round to
3- 1/ 4” x 10”
rect. 
transition
90
0  
elbow
16 Ft.         x (      )   =
Ft.    
7” round to
3 1/ 4” x 10”
rect. 
transition
8 Ft.           x (      )   =
Ft.    
7” round to
3- 1/ 4” x 10”
rect. 
transition
90
0  
elbow
23 Ft.         x (      )   =
Ft.    
Installation – 
Ducting Calculation Sheet