Friedrich US08D10B パンフレット

ページ / 17
Model
P09B
P12B
PH14B
PERFORMANCE
Cooling Capacity
Btu
9300
11600
13500
Heating Capacity
Btu
10700
Energy Efficiency Rating
EER
9.4
8.8
9.5
Coefficient of Performance
COP
2.8
Air Movement
CFM
212
235
250
Moisture Removal
Pts/hr.
5.0
6.0
6.0
SPECIFICATIONS
Refrigerant Type
R-410A
Power Supply
Volts
115
Rated Current
Cooling Amps
10.8
11.5
10.8
Heating Amps
10.8
Watts
989
1318
1421/1120
Dimensions (Inches)
W x H x D
19 1/2 x 33 1/2 x 15 1/2
Weight (Net/Shipping)
Lbs. 71/89
72/90
78/95
Carton Dimensions (Inches)
W x H x D
20 7/8 x 43 1/8 x 16 3/4
Model
Circuit Rating 
Breaker or T-D 
Fuse
Plug 
Face 
(NEMA#)
Wall Outlet 
Appearance
Power 
cord 
length
P09B
P12B
PH14B
125V - 15A
5 - 15P
6 ft.
Features/Installation/Specifications
Due to continuing research in new energy-saving technology, specifications are subject to change without notice.
LISTED
PORTABLE AIR CONDITIONERS
183H
Installation Kit
INSTALLATION KIT- Dual intake and exhaust 
hoses. Flexible, heavy duty intake/exhaust 
hoses extend from 24” to 60”. The hoses can 
be vented through a window or through a wall 
opening to the outside. 
WINDOW SLIDER KIT (Included)
Fits HORIZONTAL or VERTICAL WINDOWS
WINDOW OPENING:
Minimum: 26"*  
Maximum: 46" 
* Window slider kit can be trimmed to fit a smaller 
opening
.
NOTE: Air conditioners will provide cooling at outdoor temperatures down to 41� F and 
heat pumps will provide heating at outdoor temperatures down to 14� F with single hose installation.
Ideal Applications
• Supplemental or emergency 
cooling or heating anywhere
• Temporary cooling in computer rooms
• Guard buildings
• Construction trailers/RVs
• Workshops and garages
• Home offices
• Dorm rooms
• Bedrooms, attics and basements
• Sunrooms/enclosed patios
Installation Features
• Plugs into standard 115 volt outlet
• Easy-roll casters for portability
• All installation accessories included
• Window kit fits both vertical and horizontal 
standard and some casement slider windows
• 6 ft. long power cord
LISTED
PORTABLE AIR CONDITIONERS
183H
Extreme A/C for Hazardous Conditions
Hazardgard
®
 is specifically designed to cool living quarters, storage areas and 
other enclosures situated in hazardous locations, where specific volatile flammable 
liquids or gases are handled or used within enclosed containers or systems. 
Hazardgard meets T4 temperature classification which means unit surface tem-
peratures will not rise above 135° C/275° F.  (note: 50/60Hz model listed as T4A 
for surface temperatures to 120° C/248° F).  Operates at low ambient conditions 
without freezing at outdoor ambient temperatures as low as 7° C/45° F. Tolerates 
higher outdoor temperatures up to 55° C /130° F.
Equipment is certified in accordance with ISA 12.12.01 and NFPA 70 
(National Electric Code)
ARTICLE 501 
ARTICLE 505
Class I, Div. 2, Group A and Group B 
Class I, Zone 2, Group IIC
Class I, Div. 2, Group B 
Class I, Zone 2, Group IIB  
 
 
plus hydrogen, or “+H2”
Class I, Div. 2, Group C 
Class I, Zone 2, Group IIB 
Class I, Div. 2, Group D 
Class I, Zone 2, Group IIA
Equipment is certified in accordance with ANSI/UL 484 and SASO 2681
UL LISTED 
FOR
 CLASS 1, DIVISION 2, 
GROUPS A, B, C 
AND
 D HAZARDOUS LOCATIONS
.
Hazardous Location Room Air Conditioners
Hazardgard
®
60 Hertz models
North America
14000 to 24000 Btu
Up to 9.7 EER
50 Hertz models
International
19100 to 19500 Btu
Up to 9.0 EER
50-60 Hertz model
International-North America
50 Hertz 
60 Hertz
21000/20500 Btu 
24000/23700
8.1/8.5 EER 
8.8/8.5 EER
28