Friedrich US08D10B パンフレット
Features
Built to perform in the
harshest environments
• Offshore oil rigs, on-shore oil company
offices and refineries
• Petrochemical sites and propane fill-up
stations
• Paint and varnish storage or processing
plants
• Grain alcohol processors or storage sites
• Plant areas using strong solvents or
• Plant areas using strong solvents or
chemicals
• Munitions plants or armories
• PVC or plastics plants and processing points
• Recycling plants
• Furniture refinishing/stripping workshops
• Fertilizer plants
• Office complexes where methane is a by-
• PVC or plastics plants and processing points
• Recycling plants
• Furniture refinishing/stripping workshops
• Fertilizer plants
• Office complexes where methane is a by-
product
• Hazardous materials storage
• Container labs
• For analyzer houses/shelters
• Container labs
• For analyzer houses/shelters
Applications
• Permanent split capacitor motor
• Hermetically sealed refrigeration system
• Environmentally sealed on/off switch and gold plated contacts in
• Hermetically sealed refrigeration system
• Environmentally sealed on/off switch and gold plated contacts in
thermostat for corrosion resistance
• Solid-state control relays for compressor and fan operation
• Hot gas bypass allows the air conditioner to operate at low ambient
• Hot gas bypass allows the air conditioner to operate at low ambient
conditions without freezing at outdoor temperatures as low as 45° F (7°C)
• Hermetically sealed reciprocating compressor is cooled during the
refrigeration cycle, which allows the unit to tolerate
higher outdoor temperatures up to 130˚ F (55°C)
higher outdoor temperatures up to 130˚ F (55°C)
• Larger, commercial grade, enclosed fan motor with
hermetically sealed overload for arc-free operation.
Totally enclosed to assure efficient operation under
adverse electrical conditions
Totally enclosed to assure efficient operation under
adverse electrical conditions
• Unit utilizes field supplied, direct-wired, 15-amp circuit
with time-delay fuse that will tolerate current surge
without tripping the breaker
without tripping the breaker
• 22-gauge, G60 steel air conditioner cabinet is powder
coated for corrosion protection and to withstand years of
hard use
hard use
• High density EPS foam insulation for thermal resistance
and sound control
• Heavy duty hexacomb packaging resists damage during shipment and is
environmentally friendly
5-stage ecoat
COILS COATED FOR CORROSION RESISTANCE
MODEL SH24M20
• ElectroFin
®
5-stage, immersion ecoat process on 100% of metallic
surfaces on the outdoor coil provides outstanding corrosion resistance
protection in coastal or corrosive environments
protection in coastal or corrosive environments
ELECTROFIN BENEFITS:
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-
• Excellent adhesion characteristics
• Less than 1% thermal degradation
• Outstanding chemical resistance
• Passed 6048 hrs.ASTM B-117 Salt Spray
ELECTROFIN MEETS THE FOLLOWING:
• MIL-C-46168 Chemical Agent Resistance
-
DS2, HCI Gas
• CID A-A-52474A (GSA)
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-P-53084 (ME)-TACOM Approval
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120 cycles)
• ASTM B117-G85 Modified Salt Spray (Fog) Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for Lockheed Martin)
• MIL-STD 810F, Method 509.4 (Sand and Dust)
• MIL-P-53084 (ME)-TACOM Approval
• MIL-DTL-12468 Decontamination Agent (STB)
• DPG (Douglas Proving Grounds) Soil & Water Exposure Tests
• GM9540P-97 Accelerated Corrosion Test (120 cycles)
• ASTM B117-G85 Modified Salt Spray (Fog) Testing-2,000 hours
• ASTM B117 Salt Spray (tested by ARL for Lockheed Martin)
MODELS SH15M30A, SH20M30A, SH20M50A
• Diamonblue Advanced Corrosion Protection
®
on the
outdoor coil protects the coil against deterioration and
extends the life of the unit especially in coastal or
corrosive environments
extends the life of the unit especially in coastal or
corrosive environments
LISTED
PORTABLE AIR CONDITIONERS
183H
Due to continuing engineering research and technology, specifications are subject to change without notice. Manufactured under U.S. Design
Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. (55°C) MAXIMUM
Patent DES 368, 306 decorative front; Utility Patent 5, 622, 058. MAXIMUM outdoor ambient operating temperature is 130°F. (55°C) MAXIMUM
TEMPERATURE RATING FOR CLASS I, DIVISION 2, GROUPS A,B,C,D.
For global applications, Hazardgard cooling capacities are tested in a certified laboratory at moderate (T1*) and hot (T3*) climate conditions in
accordance with SASO (Saudi Arabian Standards Organization) Standard 2681. SASO Standard 2681 is adopted from ISO Standard 5151 for testing
and rating for performance of non-ducted air conditioners and heat pumps.
* Capacity and efficiency values at each climate conditions are available upon request.
Specifications
Installation Information
Model
Dimensions
INCHES
Window
Width
INCHES
In-Wall Installation
Finished Hole INCHES
Circuit Rating
Breaker or
T - D Fuse
Weight
Lbs.
Height
Width
Depth with
Front
Depth J Box
to Louvers
Minimum
Extension
Into Room
Into Room
Minimum
Extension
Outside
Min.
Max.
Height
Width Max. Depth
Volts - Amps
Net Shipping
SH15M30A
15
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
16
3
/
16”
26
3
/
16”
6
”
250V-15
140
167
SH20M30A
17
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
18
3
/
16”
26
3
/
16”
6
”
250V-15 (230V) 166
170
250V-20 (208V)
SH20M50A
17
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
18
3
/
16”
26
3
/
16”
6
”
250V-15
171
175
SH24M20
17
15
/
16”
25
15
/
16”
27
3
/
8”
6
”
3
1
/
16”
16
15
/
16”
27
7
/
8”
42
”
18
3
/
16”
26
3
/
16”
6
”
250V-30
180
185
(A)
Front
SIDE VIEW
(A)
Junction
Box
Box
Max.
Wall
Depth
Sleeve Dimensions Drawing
NOTE: Hazardgard unit
must be hard-wired.
Friedrich air conditioners can be found in some of
the world’s toughest locations. Oil companies rely
on us to cool offshore oil rigs in the most extreme
conditions.
the world’s toughest locations. Oil companies rely
on us to cool offshore oil rigs in the most extreme
conditions.
Model
Cooling Capacity
Electrical Characteristics
Energy
Efficiency
Ratio
Moisture
Removal
Air Direction
Controls
Air Circulation
Refrigerant
Cooling
Cooling
Btu/Hr.
Volts Rated
Amps
Watts
EER
Pints/ HR
CFM
6 0 H E R T Z - N O R T H A M E R I C A
SH15M30A
14500/14000
230/208
6.9/7.5
1495/1443
9.7/9.7
4.0
8-way
375
R-410A
SH20M30A
20000/19000
230/208
8.7/9.6
2125/2021
9.4/9.4
5.5
8-way
375
R-410A
SH24M20
24000/23700
230/208
12.6/13.5
2727/2788
8.8/8.5
8.0/7.5
8-way
385
R-401A
5 0 H E R T Z - I N T E R N A T I O N A L
SH20M50A
19500/19100
240/220
9.8/10.3
2167/2156
9.0/9.0
5.6/5.5
8-way
425
R-410A
SH24M20
21000/20500
240/220
15.0/13.2
2600/2412
8.1/8.5
7.0/7.0
8-way
360
R-410A
31
30