Zephyr AK1136B マニュアル

ページ / 19
13
T
rouble Shooting
1.  Upon completion of installation
nothing works.
2.  Light is on but blowers are not
turning at all or seems to be 
scraping on something.
3.  When blowers are on, 
something seems to be loose 
and spinning around inside.
4.  Vibration when blowers are on
5. Blowers noise
6.  Light is not working
7. Blowers seemed weak
8. Cooking fumes and smoke 
dissipates before it reaches 
the blower.
Check if unit has been plugged in, make sure that all power has been
turned back on and all electrical wiring are properly connected.
Blower blade unit might have been mounted too low and scraping
the bottom or jammed. Loosen hex screw on blade unit and adjust to
proper height.
There might have been foreign particles left within the discharge
opening or rocks, leaves, branches, etc. that might have fell in from
old duct work. Disconnect duct work to inspect and remove any 
foreign particles.
Unit might not have been secured properly on cabinet. Or cabinet
might need to be further secured into studs on wall.
Our blowers are designed to perform up to 850 cfm. A properly 
functioning motor itself should be relatively quiet. Nevertheless, due
to vacuum created by the suction, noise level up to 6 sones will be
generated when both blower unit is turned on at its maximum speed.
Employing low speeds will suffice moderate cooking such as steam-
ing, broiling etc.
Light bulb might need to be replaced. On some instances, the fragile
bulb could have been damaged during the shipping process.
Replace light bulb.
Check duct size used, duct size should be at least 3 1/4” x 10”.
Range hood WILL NOT function properly with the insufficient
duct size.
Check if duct is clogged or if dumper unit is not opening properly. A
tight mesh on a side wall cap unit might also cause restriction to the
air flow.
Use a damper type sidewall cap.
Reduce the number of elbows and length of duct work or increase
duct size. 
Check if all joints are properly connected, sealed and taped.
Check if unit is installed at the recommended height. The range hood
should also be able to cover the entire cooking area from left to right
and most areas from rear to front.
Open doors and windows might also distract air flow before it reach-
es the blowers. 
Make sure blowers are on high speed for heavy cooking.