Gaggenau RF411701 使用とお手入れ

ページ / 76
7
Connecting the Appliance
Have a technician install and connect the appliance 
according to the enclosed Installation Instructions.
Do not remove the transportation protection devices 
from the shelves and storage compartments until 
the appliance has been installed.
Always connect the water before the power.
Apart from statutory national regulations, you should 
comply with all applicable local electricity and water 
companies codes and requirements.
After installing the appliance, wait at least 1 hour 
before switching the appliance On. During 
transportation the oil in the compressor may have 
flowed into the refrigeration system.
Before switching the appliance On for the first time, 
clean the interior of the appliance (see chapter 
“Cleaning the Appliance”).
Water Connection
,
CAUTION: 
Connect the appliance to a drinking water line only:
Minimum pressure: 0.2 Mpa (2 bar)
Maximum pressure: 0.8 Mpa (8 bar)
Pressure over 0.8 MPa (8 bar): install a pressure 
limiter between drinking water connection and 
hose set:
The water may be connected only by a  competent fitter 
according to the local regulations of the appropriate 
Water Supply company.
A cold water connection is necessary for operating 
the automatic Ice Maker. The water pressure must be 
between 29 and 116 p.s.i. (2.0 and 8.0 bar). The 
installation must correspond to the local plumbing 
regulations.
Install a separate shut-off valve in the cold water 
supply line.
The Shut-Off-Valve should not be located behind 
the appliance. It is recommended that you mount 
the Shut-Off-Valve directly next to the appliance or at 
another place that is easily accessible.
When installing the water connection, observe the 
permitted installation areas for the water line.
For connection to the drinking water mains use only 
water pipes which are suitable for drinking water. 
Observe national regulations and the connection 
conditions of the local Water Supply companies.
Electrical Connection
,
WARNING: 
Avoid the risk of an electric shock!
,
WARNING: 
Insert into a grounded 3-wire receptacle. Never 
remove grounding phase. Do not use any adapters. Do 
not use any extension cords.
,
WARNING: 
Non-compliance with these instructions may result 
in death, fire or an electric shock. Improper 
connection of the protective conductor may result in 
an electric shock. If you are in doubt whether 
the appliance has been grounded properly, have 
the appliance tested by a qualified electrician or 
service technician.
Do not use extensions or distributors.
The receptacle must be installed according to the 
Installation Manual.
The appliance complies with protection class I. 
Connect the appliance to 115 V/60 Hz AC through 
a correctly installed 3-wire grounded receptacle. 
The receptacle must be protected with a 10 to 16 A 
fuse.
The appliance comes with a UL registered 3-wire 
Power Cord.
Please see the following table:
Check on the Rating Plate whether the indicated 
voltage and current type correspond with the values of 
your power supply. The location of the Rating Plate 
can be found in the chapter “Customer Service”.
,
WARNING: 
Never connect the appliance to electronic energy 
saving devices.
Our appliances can be used with power line and sine-
controlled inverters. Power line-controlled inverters 
are used for photovoltaic systems which 
are connected directly to the national grid. Sine-
controlled inverters must be used for isolated 
applications (e.g. on ships or in mountain lodges) 
which are not connected directly to the national grid.
Appliance
Maximum Simultaneous Load
Freezer 18“
3.5 amps
Freezer 24“
4.0 amps
Freezer 30“
4.5 amps