5.Ducted installation only
   Tighten the Recirculation Plate and the outlet with screws.
6. Ducted installation only
    6.1 Remove 3 1/4″×10″ vertical, 3 1/4″×10″ horizontal, or 6” round knockout   
    plates as appropriate for your ducting method.
    6.2 Attach 3 1/4″×10″ Damper/Duct connector (if using 3 1/4″×10″duct) or 6” 
    Damper/Duct connector (if using 6” round duct) over the Knockout openings.
INSTALLATION
WARNING: To reduce the risk of electrical shock, switch power off at service panel. Lock 
or tag service panel to prevent power from being switched on accidentally.
1.Remove Electrical Wiring Box Cover from inside of hood and appropriate Electrical Power 
Cable Knockout from top or back of hood.
2. Attach house power cable to hood using appropriate clamp.
3.  Hold  the  hood  in  position  under  the  cabinet.  Tighten  all  4  mounting  screws  completely  to 
secure the hood to the cabinet.
4.For  ducted  installation,  connect  ductwork  to  hood  and  use  duct  tape  to  make  joints 
secure and air-tight. Make sure the damper/duct connector enters ductwork and that the 
damper opens and closes freely.
5.Connect the house power cable to the range hood wiring: BLACK to BLACK, WHITE to WHITE 
and GREEN or BEAR WIRE to GREEN GROUD SCREW.
6.Reinstall the Bottom Cover to the hood.
9
10