Zephyr ZVOM90AG 入門ガイド

ページ / 19
10
www.zephyronline.com
Ductless recirculation is intended for applications where an exhaust duct work is not possible to be installed. 
When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust 
from cooking are drawn and fi ltered by a set of optional charcoal fi lters. The air is then purifi ed and re-
circulated back within the home.
We recommend to ALWAYS exhaust air outside of the home by employing existing or installing new duct 
work, if possible. The hood is most effective and effi cient as an exhaust hood. Only when the exhaust option 
is not possible should you recourse to converting the hood into a recirculating hood.
When converted to be a recirculating hood, a set of charcoal fi lters are required on top of its standard 
Aluminum Mesh Filter set. Order according to its Part number below. The standard Aluminum Mesh Filters 
are intended to capture residue from cooking and the optional charcoal fi lters help to purify fumes exhausted 
from cooking for re-circulation.
RECIRCULATING KIT (REQUIRED IF NO DUCTING IS USED)
Kit includes charcoal fi lters, charcoal fi lter bracket and air diverter plate.
Hood Model 
 
Part No. 
          Filters in Pkg.
ZVO-E30AG, ZVO-M90AG 
ZRC-00VO             
     2
1.   Purchase recirculating kit per the part number above
2.   Secure air diverter plate to wall below duct cover bracket. (FIG. C) Run 
8” ducting from top of hood and secure to air diverter plate. 
3.  Remove aluminum mesh fi lters from hood. Install charcoal fi lter bracket 
inside fi lter opening. Note: screws to secure charcoal fi lter bracket are 
pre-installed in the hood and must fi rst be removed. Clip charcoal fi lters 
onto charcoal fi lter bracket. (FIG. C)
4.   Re-Install aluminum mesh fi lters.
5.  Enable charcoal fi lter change indicator on control panel. (Refer to details 
on pg. 12)
6.  Charcoal fi lters must be replaced after every 120 hours of use (or 
approximately every 3 to 4 months based on the average of 1 - 2 hrs. 
of daily cooking time).  The microprocessor in the controls when set, 
will elapse and count usage time and indicate when charcoal fi lter 
replacement is required every 120 hrs.
 
NOTE: See manual included with recirculating kit for more detailed 
instructions.
Charcoal Filter Replacements
Hood Model 
 
Part No. 
          Qty to Order
ZVO-E30AG, ZVO-M90AG 
Z0F-C002                    2
DO NOT WASH CHARCOAL FILTERS.  Charcoal fi lters may need
to be changed more often depending on cooking habits.
Installation – 
Ductless Recirculating
FIG. C