Zephyr ZVOM90AG 入門ガイド

ページ / 19
Features & Controls – 
User Interface
12
www.zephyronline.com
Mesh Filter Clean Indicator (always enabled)
 - After 30 hours of fan usage the      Graphic and words “
clean mesh filter
” will illuminate indicating it is time to clean
   the mesh filters. Graphic and words will remain illuminated until reset.
 - To reset: With hood off, hold the      Button for three seconds, after three seconds the       Graphic and words “
clean mesh      
    filter
” will turn off and the 30 hour timer will reset.
Charcoal Filter Replace Indicator (disabled by default, must be enabled if recirculating hood)
 - To enable Charcoal Filter Replacement Function:
 
- With hood off, hold       Button and       Button simultaneously for three seconds. The       Graphic will illuminate for  
 
  three seconds indicating the Charcoal Filter Replacement Function is enabled.
 - To disable Charcoal Filter Replacement Function:
 
- With hood off, hold       Button and       Button simultaneously for three seconds. The        Graphic will be  
 
 
   illuminated then turn off indicating the Charcoal Filter Replacement Function is disabled.
 - After 120 hours of fan usage the       Graphic and words “
replace charcoal filter
” will illuminate indicating it is time to  
   replace the charcoal filter. Graphic and words will remain illuminated until reset.
 - To reset: With hood off, hold the       Button for three seconds, after three seconds the        Graphic and words “
replace  
    charcoal filter
” will turn off and the 120 hour timer will reset.
Clean Air Indicator
 - Clean Air is a feature that turns the fan on every 4 hours for 10 minutes to remove stagnant air in the kitchen.
 
- To enable Clean Air Function:
 
 
- With hood off, hold the      Button and       Button simultaneously for three seconds. The       Graphic and  
 
 
   words “
clean air
” will illuminate and the fan will turn on speed 1 for 10 minutes. After 10 minutes the fan  
 
 
   will turn off and the 4 hour timer will begin.
 
 
-       Graphic will remain on when Clean Air Function is enabled, even if fan is not on.
 
- To disable Clean Air Function:
 
 
- With hood off, hold the       Button and       Button simultaneously for three seconds until       Graphic  
 
 
  turns off.
 - When the Clean Air Function is enabled the fan will turn on speed 1 for 10 minutes every 4 hours of non fan usage. After 10 
   minutes the fan will turn off and the 4 hour timer will reset.
 - If the user changes the fan speed while the Clean Air Function is in use, the words “
clean air
” will turn off but the      Graphic  
   will remain illuminated. If the user presses the      Button at any time the 4 hour clean air timer will reset.