OceanAire 2OACH3634 マニュアル

ページ / 36
TO CHECK THE NUMBER OF HOURS ON THE UNIT 
 
1) Disconnect unit power, and reconnect unit power. 
2) When “888” appears in display, push and release the arrow down    
    button  
 
 
 
 
3) The first set of numbers displayed reads thousands of hours: 
    02 = 2000, 04 = 4000 hours, 00 means less than 1000 hours. 
4) The second set of numbers read hours directly: 
    58 = 58 hours. 742 = 742 hours. 
6) Add the 2 number sets together to get total hours. 
     03 and 486 = 3486 hours. 01 and 59 = 1059 hours. 
 
TOTAL HOURS REPRESENTS COMPRESSOR “RUN” TIME 
MODEL 
CODE SETTINGS 
2OACH12 
P1 = 85, P2 = 35 
2OACH18 
P1 = 80, P2 = 50 
2OACH24 
P1 = 70, P2 = 50 
2OACH36 
P1 = 85, P2 = 40 
2OACH60 
P1 = 85, P2 = 45
 
CONVERTIBLEAIRE PROGRAM PARAMETERS 
NOTICE 
 
Program Parameters are NOT controller default values. 
They are Oceanaire Factory Settings 
DISPLAY FAULTS 
LAC……. Low  AC  line  power 
AAA……. Failed Air Sensor (unit will not run) 
CON…….Empty Condensate Bucket—Units with a bucket 
 
Condensate Pump Over-Flow Alarm—Units with pump 
 
High Pressure Cut-Out—Low condenser water supply
 
correct problem, and re-set unit at HP RESET 
 
19