WineMate Wine Cooling Unit - Rear Exhaust 使用とお手入れ

ページ / 23
g. Low 
voltage 
h.  Operating 60 Hz unit at 50Hz 
i. Sealed 
system 
problem 
 
j. 
Undercharge or overcharge 
 
g.  Check power supply 
h.  Use proper 60 Hz 
i.  Call service for checking loss of 
refrigerant or restrictions 
j.  Call service to add or remove 
refrigerant 
 
7. House circuit tripping 
 
a.  Incorrect fuse or breaker 
b. Incorrect 
wirings 
c. Failed 
components 
 
a.  Check for proper fuse or breaker 
b.  Check for wirings and connections 
c.  Call service  
 
8. Noisy operation 
 
a.  Mounting area not firm 
b. Loose 
parts 
 
 
c.  Compressor overloaded due to high 
ambient temperatures or airflow 
restriction 
d. Malfunctioning 
components 
 
a.  Add support to improve installation 
b.  Check fan blades, bearings, cabinet 
washers, tubing contact and loose 
screws. 
c.  Check for airflow blockage 
 
 
d.  Call service for checking Internal 
loose, inadequate lubrication and 
incorrect wirings 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
                                                                                
- 17 -