Electrolux UL15IM20RS オーナーマニュアル

ページ / 29
20 Maintenance
PREPARING THE ICE 
MACHINE FOR STORAGE
If the ice machine is moved, not used 
for an extended period of time, or will 
be in an area that will be near freezing 
temperatures, it is necessary to remove 
any remaining water in the ice-making 
system.
WARNING
Electrical Shock Hazard. Risk 
of electrical shock or personal 
injury could occur due to 
moving components, if machine 
compartment access cover is 
removed before unplugging the ice 
machine.
CAUTION
This ice machine must have all water 
drained and removed to prevent ice 
machine damage as well as possible 
water damage to the surrounding 
area in freezing conditions. These 
damages are not covered under 
warranty.
CAUTION
Do not use any type of anti-freeze or 
other solution as a substitution for 
properly draining the ice machine.
Clean the Ice Machine
Cleaning the ice machine will help prevent 
mold and mildew growth as well as 
sanitize the ice machine for storage or 
when it is put back into service.
Draining and Removing Water 
from the Ice-Making System with 
a Gravity Drain.
  1.  Turn off the water supply to the ice 
machine.
  2.  Disconnect the water supply fitting at 
the inlet of the water valve (Figure 2).
  3.  Change the electronic control to the 
“CLEAN” position for approximately 
one minute. This will energize and 
open the water valve and remove 
most of the water from the water 
valve and the water valve’s outlet 
water line to the reservoir.
  4.  Change the electronic control to the 
“OFF” position. This will energize 
and open the drain valve to drain the 
reservoir and the ice machine drain 
system.
  5.  Unplug the ice machine from the 
electrical outlet.
Figure 2
Back view of
ice machine
Water
Supply
Line
Water Supply Fitting
Water Valve Inlet