22 Maintenance
 14.  Remove the top clamp from the vent 
tube, for easier access for the air 
hose.
 15.  Apply air pressure (approximately 10 
psi) to the end of the vent tube which 
will purge the remainder of the water 
from the drain pump and the drain 
line (Figure 6).
 16.  Reinstall the vent tube and clamp 
to the back of the ice machine and 
remove the winterization plug from 
the ice bin and save it for future use.
To Restart the Ice Machine
  1.  Reconnect or turn on the water 
supply line.
  2.  Reconnect drain tubing if removed.
  3.  Plug in the power cord to a wall 
outlet and turn the ice machine on.
  4.  Check the water inlet, drain lines, and 
fittings for any water leaks.
  5.  Check drain pump (if equipped) 
operation by pouring approximately 
two quarts of water into the ice 
storage bin. The drain pump should 
activate and discharge water (refer to 
Drain Pump section). Check for water 
leaks at all hose connections.
Figure 6
Vent
tube
Drain
line
Remove 
clamp
screw