Electrolux UL15IM20RS オーナーマニュアル

ページ / 29
24 Troubleshooting
Before You call For Service
If the unit appears to be malfunctioning, read through Normal Operation first. If the 
problem persists, check the Troubleshooting Guide. Locate the problem in the guide 
and refer to the cause and its remedy before calling for service. The problem could be 
something very simple which can be solved without a service call.
Troubleshooting Guide
DANGER
ELECTROCUTION HAZARD
NEVER attempt to repair or perform maintenance on the unit until the main 
electrical power has been disconnected.
Problem
Possible Cause
Remedy
Unit does not 
operate.
•  No electrical power to 
the unit. 
•  Cycle selector switch 
set improperly.
•  Is the ice machine’s 
power cord plugged 
in? 
•  Is the electronic control 
showing the “ICE” 
position?
•  Is a fuse blown or a 
circuit breaker been 
tripped?
•  Is the temperature of 
the room cooler than it 
normally is? 
 
 
 
 
•  Is there a drain pump 
in the ice machine?
•  Make sure power cord is 
plugged in. Check for blown 
fuse or tripped circuit breaker.
•  Make sure cycle selector switch 
is set to ICE/ON.
•  Plug the power cord into a 
grounded 3 prong outlet. 
•  Check the control to be sure it 
is in the “ICE” position. 
•  Replace a blown fuse or reset a 
tripped circuit breaker. 
•  The minimum room 
temperature is 55°F (13°C). The 
bin thermistor may be sensing 
the room temperature and shut 
off before the bin is full of ice. If 
the room temperature remains 
low the ice machine may not 
restart.
•  The drain pump is designed 
to temporarily shut the unit off 
when large quantities of water 
create a high-limit condition. 
Wait a few minutes as the drain 
pump will continue to operate 
to dispose of the excess water. 
If there is still water in the ice 
bin check the drain pump 
vent line and drain line for 
obstructions or kinking.
Unit runs but no ice 
is produced.
•  No water being 
supplied to the unit.
•  Check to see that water is 
connected and turned on to the 
unit and that ambient temperature 
does not exceed 100°F.