Page 12 
Conversion Back to Natural Gas 
If it is necessary to return the range to natural gas service, repeat all of the steps in this procedure using the 
parts that have been removed. Use the chart below to determine the orifice sizes, shutter gaps, and the air 
shutter part numbers. 
 
Natural Gas Conversion Specifications 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Burner 
Location 
Bypass 
Orifice 
Main 
Orifice 
Air Shutter  
Part No. 
Air Shutter 
Gap 
Left Rear 
81 
184 
HN A-0053-E 
.38/9.6 
Left Front 
72 
133 
HN A-0052-E 
.35/8.8 
Right Rear 
72 
133 
HN A-0052-E 
.30/7.7 
Right Front 
81 
184 
HN A-0053-E 
.39/9.9 
Center Rear 
81 
196 
HN A-0053-E 
.38/9.7 
Center Front 
81 
196 
HN A-0053-E 
.37/9.5 
Model E48DF76EPS (48-Inch) 
Burner 
Location 
Bypass 
Orifice 
Main 
Orifice 
Air Shutter  
Part No. 
Air Shutter 
Gap 
Left Rear 
81 
184 
HN A-0053-E 
.37/9.5 
Left Front 
72 
133 
HN A-0052-E 
.30/7.6 
Right Rear 
72 
133 
HN A-0052-E 
.33/8.4 
Right Front 
81 
184 
HN A-0053-E 
.37/9.4 
Center Rear 
81 
196 
HN A-0053-E 
.38/9.6 
Center Front 
81 
196 
HN A-0053-E 
.37/9.5 
Model E36DF76EPS (36-Inch) 
Burner 
Location 
Bypass 
Orifice 
Main 
Orifice 
Air Shutter  
Part No. 
Air Shutter 
Gap (IN/MM) 
Left Rear 
81 
184 
HN A-0053-E 
.37/9.5 
Left Front 
72 
140 
HN A-0052-E 
.34/8.6 
Right Rear 
81 
184 
HN A-0053-E 
.35/8.9 
Right Front 
81 
188 
HN A-0053-E 
.37/9.4 
Model E30DF74EPS (30-Inch) 