INSTALLING THE FILTER(S)
1  To remove the grease filters, grip the latch and pull it down. This will disengage 
the filters from the hood. Tilt the filters downward and remove.
2  To install the grease filters, align rear filter tabs with slots in the hood. Pull latch 
tab down, push filter up into position and release the tab. Make sure the filter is 
securely engaged after installation.
FLUE MOUNTING BRACKET
UPPER 
FLUE
LOWER 
FLUE
HOOD
MOUNTING 
SCREWS 
3.9 x 9.6mm
Figure 14
Installation
INSTALLING THE FLUE
1  Carefully slide upper flue down inside the lower flue.
2  Lift and position the flue assembly onto the top of the hood.
3  Secure the lower flue to the hood with (2) 3.9 x 9.5mm pan head 
mounting screws.
4  Raise the upper flue until its holes align with holes in the flue mount-
ing bracket (located on ceiling). Secure the upper flue with (2) 3.9 
x 9.5mm pan head mounting screws.
GREASE  
FILTERS
Figure 15
NOTE
Prior to use, remove protective film from the filter frame.