Philips BDH4222V/00 ユーザーズマニュアル

ページ / 64
User Manual BDH4222V/BDH4223V
25
If multiple commands are transmitted, make sure to wait for the 
response signals of the monitor before sending the next command. 
The following are response command signals:
Command Parameters
These remote control commands are available to send to the monitor 
using RS-232.
Response
Error
80 70
MODE ERROR
80 71
ITEM ERROR
80 72
FORMAT ERROR
Item
Cmd
Data
Details
Read
80
81-A7
Reads the monitor current 
settings for command 81 thru 
A7
Volume
81
01-64H
Set between 01-64H
Power On/Off
83
00-01
00=Off; 01=On
Brightness
85
01-64H
Contrast
86
01-64H
V-Size
87
01-64H
V-Position
88
01-64H
H-Size
89
01-64H
H-Position
8A
01-64H
Color
8E
01-64H
Tint
8F
01-64H
Sharpness
90
01-64H
Input Select
91
00-07
00=TV; 01=AV1; 02=AV2;
03=AV3; 04=Component 1;
05=Component 2; 06=RGB;
07=DVI
Recall
92
00
00=Initiate recall
Mute On/Off
95
00-01
00=Off; 01=On
PanelKey Lock
96
00-01
00=Off; 01=On
Language
97
00-02
00=English; 01=French;
02=Spanish
Color Temp
98
00-03
00=High; 01=Mid; 02=Low;
03=6500D
Bass
9A
01-64H
Treble
9B
01-64H
Balance
9C
01-64H
Woofer
9D
00-01
00=Off; 01=On
BBE
9E
00-01
00=Off; 01=On
Surround
9F
00-02
00=Off; 01=3D Stereo; 
02=3D Mono
RF Input
A0
00-01
00=Air; 01=Cable
Full Search
A1
00
00=Initiate full search
MTS
A4
00-02
00=Stereo; 01=Mono; 
02=SAP
Zoom
A5
00-05
00=16:9; 01=Panorama; 
02=4:3; 03=Zoom1; 
04=Zoom2; 05=Zoom3
PIP/POP
A7
00-03
00=Normal; 01=PIP; 
02=POP1; 03=POP2 (4:3); 
04=POP3 (16:9)