Chapter 23 Replacing or upgrading a power supply
N0060612
N0060612
Figure 150   Remove the power supply knockout bracket
7
Remove both power supply modules from the redundant power supply cage before you install 
the power supply in the main unit (see 
8
Place the redundant power supply (top down) on a flat surface. Place the power supply support 
bracket on the bottom surface of the power supply.
9
Insert a tie-wrap in the power supply support bracket lanclet. 
10 Gather together and route the motherboard 20-pin power cable (P1), the +12v power cable 
(P9), the 3.3v load cable (PB), and the PS monitor cable (PA) to the tie-wrap.
11 Secure the cables to the power supply support bracket with the tie-wrap (see 
Figure 151   Fasten the power supply support bracket cables
12 Install the power supply support bracket in the BCM400 main unit (see 
Remove this bracket to 
accommodate redundant 
power supply
Rear view
5
Secure the cables to the 
power supply bracket with 
the tie-wrap
Insert a tie-wrap in the 
power supply support 
bracket
3
Gather and route the 
cables to the tie-wrap
4
Place power supply top side 
down on flat surface
1
2
Place the support 
bracket on the power 
supply