Nortel Networks 400 4.0 ユーザーズマニュアル

ページ / 382
Chapter 25 Replacing or installing a cooling fan
325
BCM200/400 4.0 Installation and Maintenance Guide
Figure 177   Remove the BCM400 fan access panel
5
Disconnect the I/O card fan cables (see 
). For the BCM400 RFO configuration, 
disconnect both fan cables from the I/O card.
Figure 178   Disconnect the fan cable from the I/O card
6
Remove the snap rivets that hold the fan to the fan access panel. The snap rivet has two parts: 
a center pin and a collar. Gently separate the plastic rivet pin with your fingernails from the 
center of the rivet collar. Remove the rivet pin and collar from the fan access panel. Place the 
rivet pin and collar in a safe location. See 
.
Remove fan access 
panel screws
1
Remove fan access 
panel
2
I/O Card
Main Card
Disconnect from 
single fan (fan #1)
Disconnect from 
redundant fan (fan #2)