Elektra Beckum P 5500 M ユーザーズマニュアル
11
ENGLISH
• If the pump capacity lessens clean
suction strainer and filter cartridge (if
installed), replace if necessary.
installed), replace if necessary.
7.2
Danger of freezing
A
Caution!
Frost damages the pump and
Frost damages the pump and
accessories, as both always contain
water!
water!
• When there is danger of freezing,
dismount equipment and accesso-
ries and store at a freeze-proof loca-
tion (see below).
ries and store at a freeze-proof loca-
tion (see below).
7.3
Equipment dismounting
and storing
and storing
1.
Switch equipment OFF and unplug.
2.
Open pressure line (open tap or
spray nozzle) and drain water com-
pletely.
spray nozzle) and drain water com-
pletely.
3.
Drain pump completely; to do so
remove the drain plug from the
pump
remove the drain plug from the
pump
4.
Disconnect suction and pressure
lines from the equipment.
lines from the equipment.
5.
Store equipment in a frost-free
space (at least 5 °C).
space (at least 5 °C).
A
Danger!
Prior to all servicing:
Prior to all servicing:
− Switch Off.
− Unplug.
− Ensure that pressure is relieved
− Unplug.
− Ensure that pressure is relieved
from equipment and connected
accessories.
accessories.
8.1
Fault finding
Pump does not run:
• No mains voltage.
− Check cables, plug, outlet and
mains fuse.
• Mains voltage too low.
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications").
"Technical Specifications").
• Motor overheated, motor protection
relay tripped.
− After cooling off the pump will
− After cooling off the pump will
switch ON again.
− Ensure sufficient ventilation, keep
vent slots clear.
− Observe max. temperature of the
pumped medium.
• Motor hums but does not start.
− With the motor switched OFF, put
screwdriver or similar through the
fan cover's vent slots and turn the
fan.
fan cover's vent slots and turn the
fan.
• Pump blocked or out of order.
− Disassemble pump and clean.
− Clean diffusor, replace if neces-
− Clean diffusor, replace if neces-
sary.
− Clean impeller, replace if neces-
sary.
Pump does not prime correctly or
runs very noisily:
runs very noisily:
• Lack of water.
− Ensure there is a sufficient water
supply.
• Suction line leaky.
− Seal suction line, tighten screw
fittings.
• Suction head too high.
− Observe max. suction head.
− Install check valve, fill suction line
− Install check valve, fill suction line
with water.
• Suction strainer (accessory)
blocked.
− Clean, replace if necessary.
− Clean, replace if necessary.
• Check valve (accessory) blocked.
− Clean, replace if necessary.
• Water leaks between motor and
pump, Duocone seal worn.
− Replace Duocone seal.
− Replace Duocone seal.
• Pump blocked or out of order.
− see above.
Pressure too low:
• Suction line leaky or too much suc-
tion head.
− see above.
− see above.
• Pump blocked or out of order.
− see above.
A
Danger!
Repairs to electric tools must
Repairs to electric tools must
only be carried out by a qualified
electrician!
electrician!
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address.
sent to an authorised service center in
your country. See spare parts list for
address.
Please attach a description of the fault to
the electric tool.
the electric tool.
For shipping:
• Drain pump completely (see "Equip-
ment dismounting and storing").
• Ship equipment in original packing,
if possible.
The packaging of the pump can be
100 % recycled.
100 % recycled.
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled.
These instructions are printed on chlo-
rine-free bleached paper.
rine-free bleached paper.
For this equipment the following acces-
sories are available at specialist dealers.
sories are available at specialist dealers.
3
Note:
Illustrations and stock numbers
Illustrations and stock numbers
can be found at the end of these instruc-
tions.
tions.
A
Pump Installation Package,
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
1 m, thread sealing tape.
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
1 m, thread sealing tape.
B
Hydromat HM 1,
for automatic starting when water is
drawn and stopping when no water
is drawn, keeps the pump from run-
ning dry.
for automatic starting when water is
drawn and stopping when no water
is drawn, keeps the pump from run-
ning dry.
C
Hydrostop,
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
for automatic stopping when there
is a lack of water, prevents the
pump from running dry.
D
Dry-running Stop Switch,
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc.
E
Spiral Hose 1"
1) 1 m assembly, with quick
1) 1 m assembly, with quick
release screw fitting at both
ends;
ends;
2) 4 m, complete with quick
release screw fitting and
strainer with foot valve;
strainer with foot valve;
3) 7 m, complete with quick
release screw fitting and
strainer with foot valve.
strainer with foot valve.
F
Filter, 1" connection, short,
complete with washable plastic fil-
ter cartridge.
complete with washable plastic fil-
ter cartridge.
G
Disposable Filter Cartridge, short,
for mechanical preliminary filtering
of sand.
for mechanical preliminary filtering
of sand.
H
Washable Filter cartridge, short,
for mechanical preliminary filtering
of sand, reusable.
for mechanical preliminary filtering
of sand, reusable.
I
Activated Carbon Filter Cartridge,
short,
for use with chlorous water,
removes odours or discolouring.
short,
for use with chlorous water,
removes odours or discolouring.
J
Filter Cartridge Poly, short,
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers.
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers.
K
Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter.
both ends, galvanized, to connect
pump and filter.
L
Double Nipple, 1" male at boths
ends.
ends.
M
Check Valve 1" female, prevents
water backflow and pump running
dry.
water backflow and pump running
dry.
N
Thread Sealing Tape, 12 m roll.
8.
Trouble Shooting
9.
Repairs
10. Environmental Protection
11. Available Accessories