Elektra Beckum P 5500 M ユーザーズマニュアル

ページ / 44
11
ENGLISH
• If the pump capacity lessens clean
suction strainer and filter cartridge (if
installed), replace if necessary. 
7.2
Danger of freezing 
A
Caution! 
Frost damages the pump and
accessories, as both always contain
water! 
• When there is danger of freezing,
dismount equipment and accesso-
ries and store at a freeze-proof loca-
tion (see below). 
7.3
Equipment dismounting 
and storing 
1.
Switch equipment OFF and unplug. 
2.
Open pressure line (open tap or
spray nozzle) and drain water com-
pletely. 
3.
Drain pump completely; to do so
remove the drain plug from the
pump 
4.
Disconnect suction and pressure
lines from the equipment. 
5.
Store equipment in a frost-free
space (at least 5 °C). 
A
Danger! 
Prior to all servicing: 
− Switch Off. 
− Unplug. 
− Ensure that pressure is relieved
from equipment and connected
accessories. 
8.1
Fault finding 
Pump does not run: 
• No mains voltage. 
− Check cables, plug, outlet and
mains fuse. 
• Mains voltage too low. 
− Use only extension cables with
sufficient lead cross section (see
"Technical Specifications"). 
• Motor overheated, motor protection
relay tripped. 
− After cooling off the pump will
switch ON again. 
− Ensure sufficient ventilation, keep
vent slots clear. 
− Observe max. temperature of the
pumped medium. 
• Motor hums but does not start. 
− With the motor switched OFF, put
screwdriver or similar through the
fan cover's vent slots and turn the
fan. 
• Pump blocked or out of order. 
− Disassemble pump and clean. 
− Clean diffusor, replace if neces-
sary. 
− Clean impeller, replace if neces-
sary. 
Pump does not prime correctly or 
runs very noisily: 
• Lack of water. 
− Ensure there is a sufficient water
supply. 
• Suction line leaky. 
− Seal suction line, tighten screw
fittings. 
• Suction head too high. 
− Observe max. suction head. 
− Install check valve, fill suction line
with water. 
• Suction strainer (accessory)
blocked. 
− Clean, replace if necessary. 
• Check valve (accessory) blocked. 
− Clean, replace if necessary. 
• Water leaks between motor and
pump, Duocone seal worn. 
− Replace Duocone seal. 
• Pump blocked or out of order. 
− see above. 
Pressure too low: 
• Suction line leaky or too much suc-
tion head. 
− see above. 
• Pump blocked or out of order. 
− see above. 
A
Danger! 
Repairs to electric tools must
only be carried out by a qualified
electrician! 
Electric tools in need of repair can be
sent to an authorised service center in
your country. See spare parts list for
address. 
Please attach a description of the fault to
the electric tool. 
For shipping: 
• Drain pump completely (see "Equip-
ment dismounting and storing"). 
• Ship equipment in original packing,
if possible. 
The packaging of the pump can be
100 % recycled. 
Worn out power tools and accessories
contain considerable amounts of valua-
ble raw and plastic materials, which can
be recycled. 
These instructions are printed on chlo-
rine-free bleached paper. 
For this equipment the following acces-
sories are available at specialist dealers. 
3
Note: 
Illustrations and stock numbers
can be found at the end of these instruc-
tions. 
A
Pump Installation Package, 
complete with double nipple, check
valve, filter short, washable filter
cartridge, spiral hose assembly
1 m, thread sealing tape. 
B
Hydromat HM 1, 
for automatic starting when water is
drawn and stopping when no water
is drawn, keeps the pump from run-
ning dry. 
C
Hydrostop, 
for automatic stopping when there
is a lack of water, prevents the
pump from running dry. 
D
Dry-running Stop Switch, 
with 10 m cable, keeps the pump
from running dry when pumping
from tank, pool, etc. 
E
Spiral Hose 1" 
1) 1 m assembly, with quick
release screw fitting at both
ends; 
2) 4 m, complete with quick
release screw fitting and
strainer with foot valve; 
3) 7 m, complete with quick
release screw fitting and
strainer with foot valve. 
F
Filter, 1" connection, short, 
complete with washable plastic fil-
ter cartridge. 
G
Disposable Filter Cartridge, short, 
for mechanical preliminary filtering
of sand. 
H
Washable Filter cartridge, short, 
for mechanical preliminary filtering
of sand, reusable. 
I
Activated Carbon Filter Cartridge,
short, 
for use with chlorous water,
removes odours or discolouring. 
J
Filter Cartridge Poly, short, 
filled with polyphosphate, for calcif-
erous water supplied to water heat-
ers. 
K
Pipe Nipple 150 mm, 1" male at
both ends, galvanized, to connect
pump and filter. 
L
Double Nipple, 1" male at boths
ends. 
M
Check Valve 1" female, prevents
water backflow and pump running
dry. 
N
Thread Sealing Tape, 12 m roll. 
8.
Trouble Shooting 
9.
Repairs 
10. Environmental Protection 
11. Available Accessories