Chapter 2 SHD1110 Programming
Z-Wave Series Programming Guide
10
When the SHD1110 is triggered, it will send out BASIC_SET_COMMAND to the nodes of Grouping 
2.  
Refer to the 
 section to configuration parameter 1 for the setting of basic set 
command.
2.1.3  Z-Wave’s Configuration
The table below lists the configuration parameters and the value range for users to set up the 
SHD1110.
[Command Class Basic, Basic Set, Value = (255)0xFF] 
send trigger-ON command
[Command Class Basic, Basic Set, Value = 0(0x00)] 
send trigger-OFF command
Table 1   
Z-Wave Configuration Table
PARAMETER
FUNCTION
SIZE (BYTE)
VALUE
UNIT
FACTORY 
DEFAULT
DESCRIPTION
1
Basic  Set 
Level
1
0~99
%  of 
Brightness 
(Dimmer 
Level)
99 / 99
Set basic set value to 
be on (or Dim Level) 
/off.
0: Disable
2
Temperature 
Trigger-ON 
Value
1
-20~50 
or
99
Degree
30 / 99
Set temp.trigger-ON 
value to be _ degree.
99: Clear Temp. 
trigger-ON value
3
Temperature 
Trigger-OFF 
Value
1
-20~50
or
99
Degree
20 / 99
Set temp.trigger-OFF 
value to be _ degree.
99: Clear Temp. 
trigger-OFF value
4
Humidity 
Trigger-ON 
Value
1
20~90
or
99
%
50 / 99
Set humid. trigger-
ON value to be _%.
99: Clear Humid. 
trigger-ON value
5
Humidity 
Triger-OFF 
Value
1
20~90
or
99
%
40 / 99
Set humid. trigger-
OFF value to be _%.
99: Clear Humid. 
trigger-OFF value
6
Auto  Report 
(Time 
Interval)
2
1~1439 
or
99
Minute
0 / 0
Set auto report time 
interval to be _ mins.
0: Disable auto 
report