ZyXEL Communications SHD1110 ユーザーズマニュアル

ページ / 22
Chapter 2 SHD1110 Programming
Z-Wave Series Programming Guide
12
2.1.5  Wakeup Configuration
The SHD1110 stays in sleep status for the majority of time in order to conserve battery power. 
However, it can be waken up by either triggers of temperature/humidity or set time for the Z-Wave 
Controller to enable further settings.
2.1.5.1  Wakeup Time Interval
The SHD1110 stays awake for 10 seconds. If the SHD1110 receives a RF command from the Z-
Wave Controller during this period, the waking time will be extended for another 10 seconds until 
no more RF command is received. Once the wakeup time is up, the SHD1110 goes back to sleep 
status.  
2.1.5.2  Sleep Time Interval
The sleep interval can be set from 1 minute to 4660 hours (about 194 days). The unit of time is in 
seconds. The default sleep time interval is 1 hour.  
2.1.6  Command Classes
The SHD1110 supports the following Command Classes: 
• COMMAND_CLASS_BASIC
• COMMAND_CLASS_VERISON
• COMMAND_CLASS_BATTERY
• COMMAND_CLASS_WAKE_UP_V2
• COMMAND_CLASS_CONFIGURATION
• COMMAND_CLASS_ASSOCIATION_V2
• COMMAND_CLASS_MANUFACTURER_SPECIFIC
• COMMAND_CLASS_SENSOR_MULTILEVEL_V2
• COMMAND_CLASS_MULTI_INSTANCE_V2