Lamp relay
Using the lamp relay function, you can project images 
continuously. The lamp relay function automatically 
rests or switches the lamps. The lamp relay is 
performed when LAMP SELECT in the INSTALLATION 
1 menu is set to DUAL or SINGLE. 
Setting the lamp relay interval
When LAMP SELECT is set to DUAL:
Either of the lamps is automatically put to rest.
(See page 31 for menu setting.)  
1.  Display the INSTALLATION 1 menu.
2.  Select LAMP SELECT by pressing the  or  button.
1 2
LAMP SELECT
DUAL
3.  Press the ENTER button.
4.  Select DUAL   by pressing the  or  button.
LAMP SELECT
1 2
LAMP SELECT
DUAL
5.  Press the ENTER button.
6.  Select LAMP RELAY by pressing the  or  button.
LAMP RELAY
1H/24H
7.  Select 1H/24H 
 
or
 
2H/1W 
 
by pressing the  or 
 button.
1H/24H    .....Select this setting when the lamp 
is operated at a specified time of 
the day. During the continuous 
projection, LAMP 1 or LAMP 2 is 
automatically turned off for 1 hour 
in 24 hours.  After the interval is set, 
the lamps are turned off for 1 hour 
alternately at the specified interval. 
Illuminating
Off
LAMP 1
LAMP 2
1
2
3
4
5
6
7
8 (days)
At the time of power-on or menu setting
2H/1W    ......During the continuous projection, 
LAMP 1 or LAMP 2 is automatically 
turned off for 2 hours in a week. 
After the interval is set, the lamps are 
turned off for 2 hours alternately at 
the specified interval.
Illuminating
Off
LAMP 1
LAMP 2
1
2
3
4
5
6
7
8 (days)
At the time of power-on or menu setting
8.  Press the ENTER button.
•  When you select 1H/24H   or 2H/1W  , the 
box to set the lamp relay interval is displayed. 
•  When the projector is turned off, the setting is
cleared and the projector resumes operation 
from the time of the power-on or menu setting 
shown in the preceding step.
1H/24H 
NEXT LAMP RELAY
23H
0
OK
CLEAR
DEL
CANCEL
1
2
3
4
5
6
7
8
9
2H/1W 
NEXT LAMP RELAY
6D 22H
0
OK
CLEAR
DEL
CANCEL
1
2
3
4
5
6
7
8
9
9.  Move the key cursor using the direction buttons to 
select the number you want to enter and then press 
the ENTER button.
•  Maximum interval
  1H/24H   ..... 23H (23 hours)
  2H/1W   ...... 6D 22H (6 days and 22 hours)
 ← key: 
 Shifting the position of enter cursor 
to the left for each character.
 → key: 
 Shifting the position of enter cursor 
to the right for each character.
  DEL key: 
 Deleting the character in the 
position of enter cursor for each 
character.
  CLEAR 
key:  Deleting all the entered characters.
•  You can enter the value by pressing the number
buttons (0 to 9) while holding down the NUM 
button on the remote control. 
•  When the value you entered meets the following
conditions, an error dialog box is displayed at 
the screen center. 
  ∙   The value has been cleared by DEL or CLEAR 
and left blank. 
  ∙   The value you entered is out of the setting 
range.
   
1H/24H   .... 24H or over
   
2H/1W    ..... 6D 23H or over
  ∙   The value of each item is out of the setting 
range.
   
D .................. 7 or over (2H/1W   only)
   
H .................. 24 or over
10. When selecting OK, the setting is completed as 
the lamp-switching interval stored. However, when 
selecting CANCEL, the setting is completed without 
storing.
•  The display returns the LAMP RELAY menu after
selecting OK or CANCEL.
•  The setting you made is applied to NEXT LAMP
RELAY in the INFORMATION menu.
Important:
•  When you use the projector continuously, the lamp
relay may not be performed on time due to errors of 
the clock function.