Mitsubishi Electronics C64T ユーザーズマニュアル
7. Servo Parameters
7.4 Supplement
168
(c) Setting the output scale
When “0“ is set, the output will be made with the standard output unit. To change the output unit,
set a value other than “0”.
The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard
output.
set a value other than “0”.
The scale is set with a 1/256 unit. When 256 is set, the unit will be the same as the standard
output.
# No.
Abbrev Parameter
name
2263
SV063
DA1MPY
D/A output channel 1
output scale
output scale
2264
SV064
DA2MPY
D/A output channel 2
output scale
output scale
(Example 1) When SV061 = 5, SV063 = 2560
The V-phase current value will be output with 1 A/V unit to D/A output ch.1.
(Example 2) When SV063 = 11, SV064 = 128
The position droop will be output with a 2mm/Vunit to D/A output ch.2.