Napoleon Fireplaces BGD42 ユーザーズマニュアル
28
W415-0381 / H / 12.07.07
W h i t e / g r e y f i l m
forms.
forms.
Sulphur from fuel is being depos-
ited on glass, logs or combustion
chamber surfaces.
ited on glass, logs or combustion
chamber surfaces.
- clean the glass with a recommended gas fi replace glass cleaner. DO NOT
CLEAN GLASS WHEN HOT.
CLEAN GLASS WHEN HOT.
If deposits are not cleaned off regularly, the glass may become permanently
marked.
marked.
Main burner fl ame is
a blue, lazy, transpar-
ent fl ame.
a blue, lazy, transpar-
ent fl ame.
Blockage in vent.
- remove blockage. In extremely cold conditions, ice buildup may occur on the
terminal and should be removed as required.
terminal and should be removed as required.
- refer to Figure 23 to ensure correct location of storm collars.
Incorrect installation.
- check that the logs are correctly positioned.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifi ce size as specifi ed
by the rating plate values.
- check that the door gasketing is not broken or missing and that the seal is
tight.
- check that both 5" and 8" vent liners are free of holes and well sealed at all
joints.
- check that minimum rise per foot has been adhered to for any horizontal
venting.
- open air shutter to increase the primary air.
- check the input rate: check the manifold pressure and orifi ce size as specifi ed
by the rating plate values.
- check that the door gasketing is not broken or missing and that the seal is
tight.
- check that both 5" and 8" vent liners are free of holes and well sealed at all
joints.
- check that minimum rise per foot has been adhered to for any horizontal
venting.
Carbon is being de-
posited on glass, logs
or combustion cham-
ber surfaces.
posited on glass, logs
or combustion cham-
ber surfaces.
Flame is impinging on the logs
or combustion chamber.
or combustion chamber.
Air shutter has become blocked
- ensure air shutter opening is free of lint or other obstructions.
Remote wall switch is
in "OFF" position; main
burner comes on when
gas knob is turned to
"ON" position.
in "OFF" position; main
burner comes on when
gas knob is turned to
"ON" position.
Wall switch is mounted upside
down
down
- reverse.
Faulty valve.
- replace.
- replace.
Remote wall switch is ground-
ing.
ing.
- check for ground (short); repair ground or replace wire.
Remote wall switch wire is
grounding.
grounding.
Flames are very ag-
gressive.
gressive.
- fi t door assembly into the lower support brackets and secure the four door
latches.
latches.
Door is ajar
Venting action is too great.
-restrict vent exit with restrictor plate, W500-0205.
SYMPTOM
PROBLEM
TEST SOLUTION