Mitsubishi Electronics FR-A700 ユーザーズマニュアル
72
Param
e
te
r List
Parameter List
F
re
que
nc
y
det
ec
tion
41
Up-to-frequency sensitivity
0 to 100%
0.1%
10%
42
Output frequency detection
0 to 400Hz
0.01Hz
6Hz
43
Output frequency detection for reverse
rotation
rotation
0 to 400Hz, 9999
0.01Hz
9999
Seco
nd f
u
nct
ions
44
Second acceleration/deceleration time
0 to 3600/360s
0.1/0.01s
5s
45
Second deceleration time
0 to 3600/360s, 9999
0.1/0.01s
9999
46
Second torque boost
0 to 30%, 9999
0.1%
9999
47
Second V/F (base frequency)
0 to 400Hz, 9999
0.01Hz
9999
48
Second stall prevention operation
current
0 to 220%
0.1%
150%
49
Second stall prevention operation
frequency
0 to 400Hz, 9999
0.01Hz
0Hz
50
Second output frequency detection
0 to 400Hz
0.01Hz
30Hz
51
Second electronic thermal O/L relay
0 to 500A, 9999/
0 to 3600A, 9999
0 to 3600A, 9999
*2
0.01/0.1A
*2
9999
Monit
o
r f
unct
ions
52
DU/PU main display data selection
0, 5 to 14, 17 to 20,
22 to 25, 32 to 35, 39, 46,
50 to 57, 100
22 to 25, 32 to 35, 39, 46,
50 to 57, 100
1
0
54
FM terminal function selection
1 to 3, 5 to 14, 17, 18,
21, 24, 32 to 34, 46, 50,
52, 53
21, 24, 32 to 34, 46, 50,
52, 53
1
1
55
Frequency monitoring reference
0 to 400Hz
0.01Hz
60
Hz
56
Current monitoring reference
0 to 500/0 to 3600A
*2
0.01/0.1A
*2
Rated inverter
current
Aut
o
mat
ic rest
art
57
Restart coasting time
0, 0.1 to 5s, 9999/
0, 0.1 to 30s, 9999
0, 0.1 to 30s, 9999
*2
0.1s
9999
58
Restart cushion time
0 to 60s
0.1s
1s
⎯
59
Remote function selection
0, 1, 2, 3
1
0
⎯
60
Energy saving control selection
0, 4
1
0
A
u
to
m
a
tic
a
cc
e
le
ra
tio
n
/
deceler
at
ion
61
Reference current
0 to 500A, 9999/
0 to 3600A, 9999
0 to 3600A, 9999
*2
0.01A/0.1A
*2
9999
163,
62
Reference value at acceleration
0 to 220%, 9999
0.1%
9999
63
Reference value at deceleration
0 to 220%, 9999
0.1%
9999
64
Starting frequency for elevator mode
0 to 10Hz, 9999
0.01Hz
9999
⎯
65
Retry selection
0 to 5
1
0
⎯
66
Stall prevention operation reduction
starting frequency
starting frequency
0 to 400Hz
0.01Hz
60
Hz
Retry
67
Number of retries at fault occurrence
0 to 10, 101 to 110
1
0
68
Retry waiting time
0 to 10s
0.1s
1s
69
Retry count display erase
0
1
0
⎯
70
Special regenerative brake duty
0 to 30%/0 to 10%
*2
0.1%
0%
⎯
71
Applied motor
0 to 8, 13 to 18, 20, 23,
24, 30, 33, 34, 40, 43, 44,
50, 53, 54
24, 30, 33, 34, 40, 43, 44,
50, 53, 54
1
0
148,
⎯
72
PWM frequency selection
0 to 15/0 to 6, 25
*2
1
2
⎯
73
Analog input selection
0 to 7, 10 to 17
1
1
⎯
74
Input filter time constant
0 to 8
1
1
⎯
75
Reset selection/disconnected PU
detection/PU stop selection
detection/PU stop selection
0 to 3, 14 to 17
1
14
⎯
76
Fault code output selection
0, 1, 2
1
0
⎯
77
Parameter write selection
0, 1, 2
1
0
⎯
78
Reverse rotation prevention selection
0, 1, 2
1
0
⎯
79
Operation mode selection
0, 1, 2, 3, 4, 6, 7
1
0
Func-
tion
Parameter
Name
Setting Range
Minimum
Setting
Increments
Initial Value
Refer
to
Page
Customer