73
Param
e
te
r List
Parameter List
4
Mot
o
r c
onst
a
nt
s
80
Motor capacity
0.4 to 55kW, 9999/
0 to 3600kW, 9999 
*2
0.01/0.1kW 
*2
9999
81
Number of motor poles
2, 4, 6, 8, 10, 12, 14, 16, 
18, 20, 9999
1
9999
82
Motor excitation current
0 to 500A, 9999/
0 to 3600A, 9999 
*2
0.01/0.1A
  
*2
9999
83
Rated motor voltage
0 to 1000V
0.1V
200/400V 
84
Rated motor frequency
10 to 120Hz
0.01Hz
60
Hz
89
Speed control gain (Advanced magnetic 
flux vector)
0 to 200%, 9999
0.1%
9999
90
Motor constant (R1)
0 to 50
Ω, 9999/
0 to 400m
Ω, 9999 
*2
0.001
Ω/
0.01m
Ω 
*2
9999
91
Motor constant (R2)
0 to 50
Ω, 9999/
0 to 400m
Ω, 9999 
*2
0.001
Ω/
0.01m
Ω 
*2
9999
92
Motor constant (L1)
0 to 50
Ω (0 to 1000mH), 9999/
0 to 3600m
Ω (0 to 400mH), 9999 
*2
0.001
Ω (0.1mH)/
0.01m
Ω(0.01mH) 
*2
9999
93
Motor constant (L2)
0 to 50
Ω (0 to 1000mH), 9999/
0 to 3600m
Ω (0 to 400mH), 9999 
*2
0.001
Ω (0.1mH)/
0.01m
Ω(0.01mH) 
*2
9999
94
Motor constant (X)
0 to 500
Ω
 
(0 to 100%), 9999/
0 to 100
Ω (0 to 100%), 9999 
*2
0.01
Ω (0.1%)/
0.01
Ω (0.01%) 
*2
9999
95
Online auto tuning selection
0 to 2
1
0
96
Auto tuning setting/status
0, 1, 101
1
0
A
d
ju
st
able 5 
point
s V/
F
100
V/F1(first frequency)
0 to 400Hz, 9999
0.01Hz
9999
101
V/F1(first frequency voltage)
0 to 1,000V
0.1V
0V
102
V/F2(second frequency)
0 to 400Hz, 9999
0.01Hz
9999
103
V/F2(second frequency voltage)
0 to 1,000V
0.1V
0V
104
V/F3(third frequency)
0 to 400Hz, 9999
0.01Hz
9999
105
V/F3(third frequency voltage)
0 to 1,000V
0.1V
0V
106
V/F4(fourth frequency)
0 to 400Hz, 9999
0.01Hz
9999
107
V/F4(fourth frequency voltage)
0 to 1,000V
0.1V
0V
108
V/F5(fifth frequency)
0 to 400Hz, 9999
0.01Hz
9999
109
V/F5(fifth frequency voltage)
0 to 1,000V
0.1V
0V
T
h
ird f
unct
ions
110
Third acceleration/deceleration time
0 to 3600/360s, 9999
0.1/0.01s
9999
111
Third deceleration time
0 to 3600/360s, 9999
0.1/0.01s
9999
112
Third torque boost
0 to 30%, 9999
0.1%
9999
113
Third V/F (base frequency)
0 to 400Hz, 9999
0.01Hz
9999
114
Third stall prevention operation current 0 to 220%
0.1%
150%
115
Third stall prevention operation 
frequency
0 to 400Hz
0.01Hz
0Hz
116
Third output frequency detection
0 to 400Hz
0.01Hz
60
Hz
PU connect
o
r
co
mm
unicat
ion
117
PU communication station number
0 to 31
1
0
118
PU communication speed
48, 96, 192, 384
1
192
119
PU communication stop bit length
0, 1, 10, 11
1
1
120
PU communication parity check
0, 1, 2
1
2
121
Number of PU communication retries
0 to10, 9999
1
1
122
PU communication check time interval
0, 0.1 to 999.8s,  9999
0.1s
9999
123
PU communication waiting time setting 0 to 150ms, 9999
1ms
9999
124
PU communication CR/LF selection
0, 1, 2
1
1
 125
Terminal 2 frequency setting gain 
frequency
0 to 400Hz
0.01Hz
60
Hz
 126
Terminal 4 frequency setting gain 
frequency
0 to 400Hz
0.01Hz
60
Hz
Func-
tion
Parameter
Name
Setting Range
Minimum 
Setting
Increments
Initial Value
Refer 
to 
Page
Customer 