Multi-speed and Jog Frequency Setting
The L200 inverter has the capability to store and output up to 16 preset frequencies to the 
motor (A020 to A035). As in traditional motion terminology, we call this multi-speed 
profile
 capability. These preset frequencies are selected by means of digital inputs to the 
inverter. The inverter applies the current acceleration or deceleration setting to change 
from the current output frequency to the new one. The first multi-speed setting is dupli-
cated for the second motor settings (the remaining 15 multi-speeds apply only to the first 
motor).
“A” Function
Run 
Mode 
Edit
Defaults
Func.
Code
Name /
SRW Display
Description
–FEF 
(EU)
–FU 
(USA)
Units
A005 [AT] selection
Four options, select codes:
00... Select between [O] and 
[OI] at [AT]
01... [O] + [OI] ([AT] input is 
ignored)
02... Select between [O] and 
keypad potentiometer
03... Select between [OI] and 
keypad potentiometer
00
00
Hz
AT-Slct    O/OI
A011 Pot./O–L input active 
range start frequency
The output frequency corre-
sponding to the analog input 
range starting point,
range is 0.0 to 400.0
0.0
0.0
Hz
O-EXS   0000.0Hz
A012 Pot./O–L input active 
range end frequency
The output frequency corre-
sponding to the analog input 
range ending point,
range is 0.0 to 400.0
0.0
0.0
Hz
O-EXE   0000.0Hz
A013 Pot./O–L input active 
range start voltage
The starting point (offset) for 
the active analog input range,
range is 0. to 100.
0.
0.
%
O-EX%S    00000%
A014 Pot./O–L input active 
range end voltage
The ending point (offset) for 
the active analog input range,
range is 0. to 100.
100.
100.
%
O-EX%E    00100%
A015 Pot./O–L input start 
frequency enable
Two options; select codes:
00... Use offset (A011 value)
01... Use 0 Hz
01
01
O-LVL      0Hz
A016 External frequency 
filter time constant
Range n = 1 to 8, where n = 
number of samples for avg.
2.
8.
Sam-
ples
F-SAMP     00008