Electrolux 3531 WK-M ユーザーズマニュアル

ページ / 12
16
For Universal LPG the regulator is 
fitted to the gas inlet of the 
appliance so that a pressure test 
point is available. The regulator 
should be disabled by adjusting the 
regulator adjusting screw to be fully 
screwed in, but do not remove the 
locking nut from the regulator.  The 
supply pressure to the appliance is 
controlled by the regulator located 
on the LPG cylinder. This cylinder 
regulator should be adjusted to give 
a pressure of 2.75kPa at the 
appliance inlet with the large and 
simmer burners operating at 
maximum.
Use of Hose Assemblies.
If the appliance is to be installed 
using a hose assembly, then
1. The hose must be AGA certified 
    to AS/NZS 1869 as class B or  
    class D, and utilised in
    accordance with requirements of 
    AS 5601 (AG 601).
2. The connection point between the 
    consumer piping and the hose 
    must be accessible with the 
    appliance installed.
Adjusted for LPG
Typical Adjustment 
    for Natural Gas
B2004
9
The wok-unit has a special pan support 
which enables use of a wok pot with 
curved bottom.
When using cooking utensils with a 
flat bottom the diameter of the utensils 
must not be less than 26 cm.