Liebherr 110309 7084282 - 01 ユーザーズマニュアル

ページ / 18
Fig. 24 
u
To  align  the  unit  door  in  depth  Z:  Undo  top  screws
Fig. 24 (36)
, bottom hexagon head screws
 Fig. 24 (35)
 with
ring spanner
 Fig. 24 (37)
 provided, then shift the door.
u
Do not allow the knobs and sealing lips to
abut - vital for proper function!
u
Allow an air gap of 2 mm between the unit
door and the body of the unit.
For large unit doors:
u
fit  a  3rd  pair  of  mounting  brackets
Fig. 11 (34)
.
u
Use the holes pre-drilled in the handle area of
the appliance door for this purpose.
u
Check the fit of
the  door  and
adjust  if  nec-
essary.
u
Tighten 
all
screws.
Fig. 25 
u
Tighten  the  locknuts
  Fig.  25  (32)
  using  the  ring  spanner
Fig.  25  (37)
,  while  holding  fast  the  adjusting  bolts
Fig. 25 (33)
 with a screwdriver.
u
Put on and engage the up-
per covers
 Fig. 26 (38)
.
u
Place 
lateral 
covers
Fig.  26  (39)
  in  position,
slide them to the limit, then
press, until you hear them
snap into place.
u
Attach covers
 Fig. 26 (40)
sideways  and  then  draw
them  forwards  with  a
screwdriver  so  that  they
snap into place.
Fig. 26 
u
Put on and engage the covers
 Fig. 8 (5,6,7)
.
Check the following points to ensure the appliance is fitted prop-
erly. Failure to do so may lead to icing, condensate forming and
malfunction:
w
The door has to close properly
w
The unit door must not butt against the unit body
w
The seal must have a firm fit at the upper corner on the handle
side. To check, darken the room, place a torch inside the ap-
pliance at the top and close the door. If light shines through,
check the assembly.
4.4 Transporting the appliance
CAUTION
Risk of injury and danger of damage as a result of incorrect trans-
port!
u
Transport the appliance in a packed condition.
u
Transport the appliance upright.
u
Do not transport the appliance without assistance.
4.5 Installing the appliance
In the event that the appliance is damaged, contact the supplier
immediately before connecting to the mains.
The floor at the site must be flat and level.
Do not install the appliance in a location where it is exposed to
direct radiation of the sun, next to a cooker, heater and similar.
Do not install the appliance without assistance.
Standard EN 378 specifies that the room in which you install your
appliance must have a volume of 1 m
2
 per 8 g of R 600a refrig-
erant used in the appliance. If the room in which the appliance is
installed is too small, a flammable gas-air mixture may form in the
event of a leakage in the refrigeration circuit. The quantity of re-
frigerant used in your appliance is indicated on the type plate on
the inside of the appliance.
Fit the appliance in stable kitchen units only.
The following ventilation gaps must be observed:
q
The depth of the ventilation channel at the rear of the unit must
be at least 38 mm.
q
There must be a ventilation space of at least 200 cm
2
 in the
plinth and at the top of the unit.
q
Basically the principle applies: the larger the ventilation space,
the more energy-saving the appliance is in operation.
WARNING
Fire hazard due to dampness!
If live parts or the mains lead become damp this may cause short
circuits.
u
The appliance is designed for use in enclosed areas. Do not
operate the appliance outdoors or in areas where it is exposed
to splash water or damp conditions.
WARNING
Fire hazard due to refrigerant!
The refrigerant R 600a is environmentally friendly but flammable.
Escaping refrigerant may ignite.
u
Do not damage the piping of the refrigeration circuit.
WARNING
Fire hazard and danger of damage!
u
Do not place appliances emitting heat e.g. microwaves, toast-
ers etc. on the appliance!
Putting into operation
9