PRECAUTIONS TO BE OBSERVED BEFORE AND 
DURING SERVICING TO AVOID POSSIBLE EXPO-
SURE TO EXCESSIVE MICROWAVE ENERGY
(a)  Do not operate or allow the oven to be operated with the door open.
(b)  Make the following safety checks on all ovens to be serviced before activating the magnetron or other 
microwave source, and make repairs as necessary: () interlock operation, (2) proper door closing, (3) 
seal and sealing surfaces (arcing, wear, and other damage), (4) damage to or loosening of hinges and 
latches, (5) evidence of dropping or abuse.
(c)  Before turning on microwave power for any service test or inspection within the microwave generating 
compartments, check the magnetron, wave guide or transmission line, and cavity for proper alignment, 
integrity, and connections.
(d)  Any defective or misadjusted components in the interlock, monitor, door seal, and microwave genera-
tion and transmission systems shall be repaired, replaced, or adjusted by procedures described in this 
manual before the oven is released to the owner.
(e)  A  microwave  leakage  check  to  verify  compliance  with  the  Federal  Performance  Standard  should  be 
performed on each oven prior to release to the owner.
(RD800U)
BEFORE SERVICING
Before servicing an operative unit, perform a microwave emission check as per the Microwave 
Measurement Procedure outlined in this service manual.
If  microwave  emissions  level  is  in  excess  of  the  specified  limit,  contact  ELECTROLUX  HOME 
PRODUCTS, INC. immediately.
If the unit operates with the door open, service person should ) tell the user not to operate the 
oven and 2) contact ELECTROLUX HOME PRODUCTS, INC. and Food and Drug Administration's 
Center for Devices and Radiological Health immediately.
Service personnel should inform ELECTROLUX HOME PRODUCTS, INC. of any certified unit 
found with emissions in excess of 4mW/cm
2
. The owner of the unit should be instructed not to use 
the unit until the oven has been brought into compliance.