WARNING TO SERVICE PERSONNEL
Microwave ovens contain circuitry capable of pro-
ducing very high voltage and current, contact with 
following  parts 
  may  result  in  a  severe,  possibly 
fatal, electrical shock.
(Example)
High  Voltage  Capacitor,  High  Voltage  Power 
Transformer,  Magnetron,  High  Voltage  Rectifier 
Assembly,  High Voltage Harness etc..
Read the Service Manual carefully and follow all 
instructions.
Before Servicing
.  Disconnect the power supply cord  
,  and  then 
remove outer case.
2.  Open the door and block it open.
3.  Discharge high voltage capacitor.
WARNING: RISK OF ELECTRIC SHOCK. 
DISCHARGE THE HIGH-VOLTAGE 
CAPACITOR BEFORE SERVICING.
The  high-voltage  capacitor  remains  charged  about  60 
seconds after the oven has been switched off. Wait for 
60 seconds and then short-circuit the connection of the 
high-voltage capacitor (that is the connecting lead of the 
high-voltage rectifier) against the chassis with the use of 
an insulated screwdriver. 
Whenever troubleshooting is performed the power supply  
must be disconnected. It may, in some cases, be necessary 
to connect the power supply after the outer case has been 
removed, in this event,
.  Disconnect  the  power  supply  cord,  and  then  remove 
outer case.
2.  Open the door and block it open.
3.  Discharge high voltage capacitor.
4.  Disconnect  the  leads  to  the  primary  of  the  power 
transformer.
5.  Ensure  that  these  leads  remain  isolated  from  other 
components  and  oven  chassis  by  using  insulation 
tape.
6.  After that procedure, reconnect the power supply cord.
When the testing is completed,
.  Disconnect  the  power  supply  cord,  and  then  remove 
outer case.
2.  Open the door and block it open.
3.  Discharge high voltage capacitor.
4.  Reconnect  the  leads  to  the  primary  of  the  power 
transformer.
5.  Reinstall the outer case (cabinet).
6.  Reconnect the power supply cord after the outer case 
is installed.
7.  Run the oven and check all functions.
After repairing
.  Reconnect all leads removed from components during 
testing.
2.  Reinstall the outer case (cabinet).
3.  Reconnect the power supply cord after the outer case 
is installed.
4.  Run the oven and check all functions.
Microwave ovens should not be run empty. To test for the 
presence of microwave energy within a cavity, place a cup 
of cold water on the oven turntable, close the door and set  
the power to HIGH and set the microwave timer for two (2) 
minutes. When the two minutes has elapsed (timer at zero) 
carefully check that the water is now hot. If the water remains 
cold carry out 
Before Servicing procedure and re-examine 
the connections to the component being tested. 
When all service work is completed and the oven is fully 
assembled, the microwave power output should be checked 
and microwave leakage test should be  carried out.
Don't Touch !