Serial Port Configuration
4-23
minal’s serial port parameters match those on the 
Switch 2000 TR. This allows you to continue to access 
the management facility from the equipment after 
you change the serial port parameters.
The Serial Port Setup screen displays the following:
Connection Type
Local/remote
Select Remote if you wish to manage 
the Switch 2000 TR using a modem; DCD Control 
and DSR Control will be enabled. For all other cases 
this should remain at Local.
DCD Control
Enabled/Disabled
This field applies to local con-
nection types. This determines if DCD needs to be 
asserted for remote connection and if the connection 
requires that DCD be released. Refer to your terminal 
or modem documentation for more information.
DSR Control
Enabled/Disabled
This field applies only to local 
connection types. This determines if DSR needs to be 
asserted for remote connection and if the connection 
requires that DSR be released. Refer to your terminal 
or modem documentation for more information.
Flow Control
XON/XOFF/NONE/RTS-CTS 
Unidirectional/RTS-CTS Bidirectional
Select the 
correct flow control option for your terminal or 
modem. Refer to your terminal or modem documen-
tation for more information.
Auto Config
Enabled/Disabled
The Switch 2000 TR can 
auto-configure the line speed (baud) to work with 
your VT100-compatible terminal.
Speed
1200/2400/9600/19200
Select the correct line 
speed (baud) for your terminal or modem.
Char Size
8
Displays the character bit size for the Switch 2000 
TR. You should set your terminal to the same value.
Parity
NONE
Displays the parity setting for the Switch 
2000 TR. You should configure your terminal to the 
same setting.
Stop Bit
1
Displays the Stop Bit setting for the Switch 2000 
TR. You should configure your terminal to the same 
setting.