Cabletron Systems FDDI ユーザーズマニュアル

ページ / 32
 
7F06-02 FDDI SmartSwitch Interface Module User’s Guide
2-1
 
CHAPTER 2
NETWORK REQUIREMENTS
 
Before installing Cabletron Systems 7F06-02 Module, review the network 
requirements outlined in this chapter. All requirements included in this 
chapter should be met to ensure satisfactory performance of the 7F06-02 
Module. Failure to do so may result in unsatisfactory network 
performance.
 
2.1
FPIM MODULE SPECIFICATIONS
 
This module uses Fiber Port Interface Modules (FPIM) to provide front 
panel cable connections. The FPIMs are user-installable. Refer to Section 
3.2, Installing FPIMs. 
 
2.1.1
FPIM-00 and FPIM-01
 
The FPIM-00 and FPIM-01 provide a multimode fiber connection. The 
FPIM-00 uses a MIC style connector and the FPIM-01 uses an SC type 
connector. The specifications for both devices are listed in Table 2-1, 
while the transmitter power parameters are provided in Table 2-2.
 
Table 2-1
FPIM-00 and FPIM-01 Specifications
 
Parameter
Typical Value
Worst 
Case
Worst 
Case 
Budget 
Typical 
Budget
 
Receive 
Sensitivity
-30.5 dBm
-28.0 dBm
 —
Peak Input 
Power
-7.6 dBm
-8.2 dBm
 —
 —