Cabletron Systems FDDI ユーザーズマニュアル

ページ / 32
 
Chapter 2: 
 
Network Requirements
 
2-2
7F06-02 FDDI SmartSwitch Interface Module User’s Guide
 
The link distance is up to 2 kilometers on the multimode fiber optic cable 
as specified by ANSI MMF-PMD.
 
2.1.2
FPIM-02 and FPIM-04
 
The FPIM-02 has an RJ-45 connector supporting an Unshielded Twisted 
Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting 
a Shielded Twisted Pair (STP) connection. The pinouts for both are listed 
in Table 2-3.
The link distance is up to 100 meters on unshielded twisted pair cable as 
specified by ANSI TP-PMD.
 
Table 2-2
Transmitter Power Parameters 
 
Parameter
Typical Value
Worst 
Case
Worst 
Case 
Budget
Typical 
Budget
 
50/125 
 
µ
 
fiber
-13.0 dBm
-15.0 dBm
13.0 dB
17.5 dB
62.5/125 
 
µ
 
m fiber
-10.0 dBm
-12.0 dBm
16.0 dB
20.5 dB
100/140 
 
µ
 
fiber
-7.0 dBm
-9.0 dBm
19.0 dB
23.5 dB
Error Rate
Better than 10
 
-10
 
Table 2-3
FPIM-02 and FPIM-04 Pinouts
 
Pin Number
Represents
Pin Number
Represents
 
1
Transmit+
5
NA
2
Transmit-
6
NA
3
NA
7
Receive+
4
NA
8
Receive-