Multi-Tech Systems MVP210-SS ユーザーズマニュアル

ページ / 415
Technical Configuration  
 MultiVOIP 
User 
Guide 
146 
 
 
E&M Interface Parameter Definitions (cont’d) 
Field Name 
Values 
Description 
Dialing Options (cont’d)
 
 
Flash Hook Options fields
 
 
Generation integer 
values, 
in 
milliseconds 
Length of flash hook that will 
be generated and sent out when 
the remote end initiates a flash 
hook and it is regenerated 
locally.  Default = 600 ms.  
Detection 
Range 
for 
Min
and 
Max
.,
 
50 1500 
milliseconds 
For a received flash hook to be 
regarded as such by the 
MultiVOIP, its duration must 
fall between the minimum and 
maximum values given here.