Multi-Tech Systems MVP210-SS ユーザーズマニュアル

ページ / 415
Technical Configuration  
 MultiVOIP 
User 
Guide 
148 
 
 
DID Interface Parameter Definitions (
cont’d)
 
Field Name 
Values 
Description 
DID Options (cont’d) 
 
Start Modes  
Immediate Start, 
Wink Start, 
Delay Dial 
For Wink Start, the voip detects 
the off-hook condition.  Then 
the voip reverses battery 
polarity for a specified time 
(140-290 ms; a “wink”) and then 
becomes ready to receive dial 
digits. 
For Delay Dial, the voip detects 
detects the off-hook condition.  
Then the voip reverses battery 
polarity for a specified time 
(reverse polarity duration has 
wider acceptable range than for 
Wink Start) and then becomes 
ready to receive dial digits. 
Wink Timer 
(in ms) 
integer values,  
in milliseconds 
This is the length of the wink 
for Wink Start and Delay Dial 
signaling modes.. 
Applicable only when Start 
Mode
 parameter is set to “Wink 
Start” or “Delay Dial.” 
Dialing Options 
 
Inter Digit 
Timer 
integer values, 
in seconds 
This is the length of time that 
the MultiVOIP will wait 
between digits.  When the time 
expires, the MultiVOIP will 
look in the phonebook for the 
number entered.  
Default = 2. 
Message 
Waiting 
Indication 
-- 
Not applicable to DID-DPO 
interface.   
Inter-Digit 
Regeneration 
Timer 
integer values, 
in milliseconds 
This parameter is applicable 
when digits are dialed onto a 
DID-DPO channel after the 
connection has been made.  The 
length of time between the 
outputting of DTMF digits. 
Default = 100 ms.