Delta Electronics DOP-A/AE/AS 接続ガイド

ページ / 137
Delta DOP Series HMI Connection Manual|DOP-A/AE/AS Series 
Revision January, 2008, Doc. Name: 2007PDD23000007 
 
 
1-39 
HUST CNC Controller 
A. HMI factory settings 
Baud rate: 9600, 7, EVEN, 2. 
Controller station number: 0. 
Control area/status area: W0 / W10. 
B. Definition of controller Read/Write address 
Registers 
Read/Write Range 
Register Type 
Format 
Word No. 
Bit No. 
Data Length 
Word Register 
Wn 
n: 0 ~ 13500 
N/A 
Word 
Double Word Register  Dn 
n: 0 ~ 13500 
N/A 
Double Word 
NOTE
  
1)  The unit for Hust CNC controller is D Word and Wn is the low word of Dn. 
Contacts 
Read/Write range 
Contact Type 
Format 
Word No. 
Bit No. 
BIT_DEVICE_B 
Bm.n 
m: 0 ~ 13500 
n: 0 ~ 31 
BIT_DEVICE_I 
In 
N/A 
n: 0 ~ 255 (8 DW) 
BIT_DEVICE_O 
On 
N/A 
n: 0 ~ 255 (8 DW) 
BIT_DEVICE_C 
Cn 
N/A 
n: 0 ~ 255 (8 DW) 
BIT_DEVICE_S 
Sn 
N/A 
n: 0 ~ 255 (8 DW) 
BIT_DEVICE_A 
An 
N/A 
n: 0 ~ 1023 (32 DW) 
C. Connections (Connector Pinouts) 
RS-232 
DOP Series 
9 pin D-SUB male (RS-232) 
Controller 
9 pin D-SUB male (RS-232) 
Controller 
9 pin D-SUB male 
(RS-232) 
RXD (2)
(2) TXD
TXD (3)
GND (5)
(3) RXD
(5) SG
(8) RTS
(7) CTS
 
 
 
 
 
 
 
Top View 
Pin1