Citizen CL-S700R ユーザーズマニュアル
Chapter 2 Operating Principles
2-4. Interface
CL-S700/CL-S703/CL-S700R
2-52
2-4. Interface
2-4-1. Serial Interface
(1) Specifications
System
Start/stop asynchronous full duplex communication
Signal level
RS-232C
Baud rate
2400, 4800, 9600, 19200, 38400, 57600, 115200 bps
Data length
7 bits, 8 bits
Stop bit
1 bit, 2 bits
Parity Odd,
even,
none
Connector
D-SUB DBR40-251F100 25PIN (ACON)
(2) Signal line and pin assignment
Pin No. Signal Abbr.
Signal name
Function
1
FG
Frame ground
Protective grounding
2
TXD
Transmit Data
Signal line that transmits data from the printer to
the host
the host
3
RXD
Receive data
Signal line that transmits data from the host to
the printer
the printer
4 RTS
Request
To
Send
Pulled up to +5.4V through 3.3 kΩ
5 NC
------
Not
used
6
DSR
Data Set Ready
Signal line that is active when the host can
interface with the printer
interface with the printer
7
SGND
Signal ground
Signal grounding line
8-13 NC
------
Not
used
14
VCC
+5V
(Factory use only )
15-19 NC
------
Not
used
20 DTR
Data
Terminal
Ready
Signal line that is active when the printer can
interface with the host
interface with the host
21-25 NC
------
Not
used