Citizen CL-S700R ユーザーズマニュアル

ページ / 257
Chapter 2 Operating Principles 
2-4. Interface 
CL-S700/CL-S703/CL-S700R
 2-52 
2-4. Interface 
2-4-1. Serial Interface 
(1) Specifications 
 
System 
Start/stop asynchronous full duplex communication 
Signal level 
RS-232C 
Baud rate 
2400, 4800, 9600, 19200, 38400, 57600, 115200 bps 
Data length 
7 bits, 8 bits 
Stop bit 
1 bit, 2 bits 
Parity Odd, 
even, 
none 
Connector 
D-SUB DBR40-251F100 25PIN (ACON) 
 
(2)  Signal line and pin assignment 
 
Pin No.  Signal Abbr. 
Signal name 
Function 
FG 
Frame ground 
Protective grounding 
TXD 
Transmit Data 
Signal line that transmits data from the printer to 
the host 
RXD 
Receive data 
Signal line that transmits data from the host to 
the printer 
4 RTS 
Request 
To 
Send 
Pulled up to +5.4V through 3.3 kΩ 
5 NC 
------ 
Not 
used 
DSR 
Data Set Ready
Signal line that is active when the host can 
interface with the printer 
SGND 
Signal ground 
Signal grounding line 
8-13 NC 
------ 
Not 
used 
14 
VCC 
+5V 
(Factory use only ) 
15-19 NC 
------ 
Not 
used 
20 DTR 
Data 
Terminal 
 
Ready 
Signal line that is active when the printer can 
interface with the host 
21-25 NC 
------ 
Not 
used