Citizen CL-S700R ユーザーズマニュアル
![Citizen](https://files.manualsbrain.com/attachments/d78df7d8b34489fa71def4f796e8b7a215acb3c7/common/fit/150/50/aa1866962237fbb19e2a2bb7ece54cc1ce07476181720dd51672808331ff/brand_logo.png)
Chapter 2 Operating Principles
2-4. Interface
CL-S700/CL-S703/CL-S700R
2-54
2-4-2. Parallel Interface
(1) Specifications
Transmission system 8-bit parallel data
Receive buffer size
Receive buffer size
16K bytes
Transmission modes
Compatible mode
It is an asynchronous forward channel mode to send the byte width
data from the host to the printer. The interface line of the data is
operated in accordance with signal line definitions of Centronics.
NIBBLE mode
It is an asynchronous reverse channel mode to send the data from
the printer to the host. In Nibble mode, 4-bit data (half byte) is sent at
a time using the 4 status lines (FAULT, SELECT, PE, and BUSY). To
send one complete byte data, the printer sends 2 nibbles (8 bits in
total) to the host. Nibble mode is usually combined with Compatible
mode to create a complete bi-directional channel.
ECP mode
ECP mode permits bi-directional asynchronous data transmission,
and by means of interlock handshake, it does not require the timing
necessary with Compatible mode.
It is an asynchronous forward channel mode to send the byte width
data from the host to the printer. The interface line of the data is
operated in accordance with signal line definitions of Centronics.
NIBBLE mode
It is an asynchronous reverse channel mode to send the data from
the printer to the host. In Nibble mode, 4-bit data (half byte) is sent at
a time using the 4 status lines (FAULT, SELECT, PE, and BUSY). To
send one complete byte data, the printer sends 2 nibbles (8 bits in
total) to the host. Nibble mode is usually combined with Compatible
mode to create a complete bi-directional channel.
ECP mode
ECP mode permits bi-directional asynchronous data transmission,
and by means of interlock handshake, it does not require the timing
necessary with Compatible mode.
Signal level
IEEE1284 compatible
(2) Signal line and pin assignment
Pin No. Signal name
I/O
Function in Compatible Mode
1
STROBE
Input
Strobe signal to read in 8-bit data
2-9
DATA0-7
Input
8-bit parallel signal
10
ACKNLG
Output 8-bit data request signal
11
BUSY
Output Signal specifying printer busy
12
PERROR
Output Signal specifying media end
13
SELECT
Output Signal specifying if the printer is on-line (printing enabled)
or off-line
14 AUTOFD
Input Invalid
(ignored)
15 NC
--- Not
used
16 SGND
--- Signal
ground
17 FGND
--- Frame
ground
18
P.L.H
Output Peripheral logic high (pulled up to +5V at 1KΩ)
19-30 GND
---
Ground for twisted pair return
31 PRIME
Input Printer
reset
32
FAULT
Output Signal specifying printer error
33 GND
--- Signal
ground
34 NC
--- Not
used
35 FUSE
--- Not
used
36 SELECTIN Input Invalid
(ignored)