2-4-2. Parallel Interface 
(1) Specifications 
 
Transmission system 8-bit parallel data 
Receive buffer size 
16K bytes 
Transmission modes
Compatible mode 
It is an asynchronous forward channel mode to send the byte width 
data from the host to the printer. The interface line of the data is 
operated in accordance with signal line definitions of Centronics. 
NIBBLE mode 
It is an asynchronous reverse channel mode to send the data from 
the printer to the host. In Nibble mode, 4-bit data (half byte) is sent at 
a time using the 4 status lines (FAULT, SELECT, PE, and BUSY). To 
send one complete byte data, the printer sends 2 nibbles (8 bits in 
total) to the host. Nibble mode is usually combined with Compatible 
mode to create a complete bi-directional channel. 
ECP mode 
ECP mode permits bi-directional asynchronous data transmission, 
and by means of interlock handshake, it does not require the timing 
necessary with Compatible mode. 
Signal level 
IEEE1284 compatible 
  
(2)  Signal line and pin assignment 
 
Pin No.  Signal name 
I/O 
Function in Compatible Mode 
STROBE 
Input 
Strobe signal to read in 8-bit data 
2-9 
DATA0-7 
Input 
8-bit parallel signal 
10 
ACKNLG 
Output  8-bit data request signal 
11 
BUSY 
Output  Signal specifying printer busy 
12 
PERROR 
Output  Signal specifying media end 
13 
SELECT 
Output  Signal specifying if the printer is on-line (printing enabled) 
or off-line 
14 AUTOFD 
Input Invalid 
(ignored) 
15 NC 
---  Not 
used 
16 SGND 
---  Signal 
ground 
17 FGND 
---  Frame 
ground 
18 
P.L.H 
Output  Peripheral logic high (pulled up to +5V at 1KΩ) 
19-30  GND 
--- 
Ground for twisted pair return 
31 PRIME 
Input Printer 
reset 
32 
FAULT 
Output  Signal specifying printer error 
33 GND 
---  Signal 
ground 
34 NC 
---  Not 
used 
35 FUSE 
---  Not 
used 
36 SELECTIN  Input Invalid 
(ignored)