ZyXEL Communications IES-612-51A ユーザーズマニュアル
Chapter 43 Alarm Commands
IES-612-51A User’s Guide
287
43.8 Alarm History Show Command
Syntax:
ras> alarm history show [<severity>|all] [<alarm>|all] [<condition>|all]
[<sdate>|all] [<edate>|all] [for|rev] [detail]]
where
This command displays historic alarms by severity, alarm category, alarm condition and/or
dates.
dates.
The following example displays the historic critical level alarms for all alarm categories, and
all conditions.
all conditions.
43.9 Alarm History Clear Command
Syntax:
ras> alarm history clear [<alarm>|all <condition>|all] <severity>
This command removes historic alarm entries by alarm category, alarm condition or severity.
The following example removes the historic minor level alarms for all alarm categories, and
all conditions.
all conditions.
<sdate>
=
The start date, in
yyyy/mm/dd
format.
<edate>
=
The end date, in
yyyy/mm/dd
format.
[for|rev]
=
The displaying order. Use
for
to display in chronological
order starting from the oldest alarm. Use
rev
to display in
reverse chronological order starting from the most recent
alarm.
alarm.
[detail]
=
Display in-depth alarm information.
Figure 142 Alarm History Show Command Example
ras> alarm history show major all all all all rev detail
no alarm condition severity timestamp source
------ ------ -------------------- -------- -------------- -------
1 enet -down major 01/01 00:00:12 enet 1
* NTENET1:GbE interface is down
2 enet +down major 01/01 00:00:10 enet 1
* NTENET1:GbE interface is down
Figure 143 Alarm History Clear Command Example
ras> alarm history clear minor