TROUBLESHOOTING
Note:
  In  normal  operation,  LED  blinks  once 
every two seconds; also, LED will be on for one 
second after every valid command received by the 
receiver/valve' these are not error codes.
Failure codes can occur anytime after the pilot 
burner is lit. Failure code timing is 1/4 second 
on, 1/2 second off.
Sequence is failure code followed by LED not 
blinking for four seconds.
In the event of multiple failure codes, the next 
failure code follows the previous failure code by 
approximately 3 seconds.
LED Failure Code
(No. of Blinks) 
Service Action
 
Replace valve.
 
Confirm  stepper  motor  
 
 
connection exists.
 
Confirm fan connection  
 
 
exists and works.
 
Replace thermopiles.
 
Device too hot. Turn on fan  
 
 
or if applicable, open glass  
 
 
doors.
 1 short blink 
Normal operation
LED Failure Codes and Service Action
 WARNING: Turn off and unplug heater and let cool before servicing. 
Only a qualified service person should service and repair heater.
IMPORTANT: Valve system troubleshooting should only be accom-
plished by a qualified service technician.
Note: 
Before troubleshooting the gas control system, be sure external gas shut off valve (located at gas 
supply inlet) is in the "ON" position.
POSSIBLE CAUSE
REMEDY
OBSERVED PROBLEM
1. Defective ignitor (no spark 
at electrode)
2. Defective  or  misaligned 
electrode at pilot (spark at 
electrode)
3. Gas supply pressure errant
4. Pilot orifice plugged
1. Defective  pilot  generator 
(thermocouple)
Spark ignitor will not light pilot 
after  repeated  triggering  of  ig-
nitor button
Pilot will not stay lit after care-
fully  following  the  lighting 
instructions
1. Check for spark at electrode 
and  pilot;  if  no  spark  and 
electrode  wire  is  properly 
connected, replace ignitor
2. Using a match, light pilot. If 
pilot lights, turn off pilot and 
trigger the ignitor button again. 
If pilot lights, an improper gas 
mixture caused the bad lighting 
and a longer purge period is 
recommended. If pilot will not 
light, check gap at electrode 
and pilot - gap should be 1/8" 
to have a strong spark. If gap 
measures 1/8", replace pilot 
3. Check  inlet  gas  pressure.  It 
should be within the limits as 
marked on the rating plate
4. Clean or replace pilot orifice
1. Check  pilot  flame,  it  must 
impinge  on  thermocouple 
(see  Figure  13,  page  11). 
Clean and/or adjust pilot for 
maximum flame impingement 
on thermocouple. Ensure that 
the  connection  between  the 
valve and thermocouple are 
tight and secure.