Recommended Programming Procedure 
The following is a step-by-step procedure recommended for programming your VISTA-50P/VISTA-50PUL system. 
1.  Set the keypads (and other peripheral devices) to the appropriate addresses. 
2.  Set factory defaults by pressing 
97. 
This will automatically enable keypad addresses 00-03, so be sure at least one keypad is set to one of these 
addresses.  
3.  Program system-wide (global) data fields.  
Using the programming form as a guide, enter program mode and program all system-wide programming 
fields.  These options affect the entire system, regardless of partitions. They include control options, 
downloader and dialer options, RF options, event logging options, etc. Refer to the Program Field Index for a 
listing of the program fields and their function.  
Note that field 2
00 (number of partitions) must be programmed before continuing. 
4.  Program partition-specific fields. 
When the system-wide fields have been programmed, program all partition-specific programming fields by 
first pressing 
91 to select a partition (while still in data field program mode). Then enter the first partition-
specific field number 
09. When you are finished, the next partition-specific field is automatically displayed. 
Partition-specific fields can have different values for each partition. To program the fields for the next partition, 
press 
91, enter the desired partition number, then enter field 
09. Refer to the PROGRAMMING section in 
the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide for detailed instructions. 
5.  Use #93 Menu Mode for device programming. 
Refer to Device Programming in this guide to assign keypad ID numbers and default partitions for each 
keypad, and to selectively suppress certain keypad sounding options.  Also use this mode to assign RF 
receivers, relay modules, the VIP module, the ECP Long Range Radio, and the VISTA Gateway Module. 
6.  Use #93 Menu Mode for zone programming. 
Refer to Zone Programming in this guide to program zone response types, assign right loop zones and 
wireless zones, assign zones to partitions, and to program alarm report codes.  
7.  Use #93 Menu Mode for programming outputs. 
Refer to Output Programming in this guide to program desired output operation. 
8. Program 
Communication 
options. 
Refer to System Communication section in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup 
Guide 
for detailed instructions. Then use #93 menu mode to program report codes. 
9.  Use #93 Menu Mode for programming alpha descriptors. 
Refer to Alpha Programming in this guide to enter zone and partition descriptors and a custom installer’s 
message. 
10. Use #93 Menu Mode for relay voice descriptors and custom word substitutes. 
Refer to Relay Voice Descriptors in this guide for further instructions for programming relay descriptors to be 
annunciated by the VIP module, as well as the Custom Index section for custom word substitutes. 
11. Use #80 Mode for programming schedules. 
Refer to the Scheduling Menu Prompts in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup 
Guide
 to program open/close schedules, temporary and holiday schedules, limitation of access schedules, 
and time-driven events. 
12. Define user access codes. 
Refer to User Access Codes in the ADEMCO VISTA-50P/VISTA-50PUL Installation and Setup Guide to 
program authority level, O/C reporting option, partition assignments, and RF key assignments for each user. 
13. Exit Programming Mode. 
Exit programming mode by pressing either 
98 or 
99. Additional entries of 
99 are required if the exit is 
being done from fields 1
00 and above. 
To prevent re-access to programming mode using the Installer’s code, use 
98. The only way to re-access 
programming mode is by depressing both the [
] and [#] keys at the same time within 30 seconds of power-
up. 
Exiting by using 
99 always allows reentry into programming mode using the Installer code. Either way of 
exiting allows access via downloading.  Note that if local programming lockout is set via downloading, 
programming mode cannot be entered at the keypad.